{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK2200-1DQ00-1AA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK2200-1DQ00-1AA3","canonicalUrl":"https://aoctrl.com/siemens/3RK2200-1DQ00-1AA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RK2200-1DQ00-1AA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens K60 compact digital I/O module, 3RK2200-1DQ00-1AA3, 8 PNP inputs, IP67, 20-30 VDC, 8 x M12 sockets, requires two AS-i addresses.","salesMarkdown":"## 8-input AS-i slice for wet-area field deployment The 3RK2200-1DQ00-1AA3: This is a K60 compact digital input module — 8 PNP inputs across 8 M12 sockets, designed for AS-i (Actuator-Sensor Interface) networks where you need IP67-rated I/O right at the machine, not back in a cabinet. The module requires two consecutive AS-i addresses to map all 8 inputs — addresses 1 and 2 cover the first four sockets, with the remaining four sockets on address 2. Plan your address table accordingly; this is not a single-slot slave. Sensor supply is 20-30 VDC fed through PIN 1 of each M12 socket, with common return on PIN 3. The input circuit is PNP — sourcing sensors only; no NPN compatibility here. ## IP67, DIN-rail, and the K60 mounting plate IP67 rating means the module body and M12 sockets survive washdown — suitable for food-and-bev lines, car wash stations, or any wet environment where a panel-mount I/O card would need a sealed enclosure. Mounts on standard DIN rail or via the K60 mounting plate for wall mounting. The module ships without the mounting plate — order separately if you are not using DIN rail. Dimensions are 60 mm wide, 152 mm tall, 29 mm deep — compact enough for a 200 mm junction box. Each M12 socket has a dedicated ground terminal on PIN 5, all tied to the grounding wrist strap in the mounting plate. This keeps shield continuity clean — important when running sensor cables alongside power in the same harness. ## Active production — sourced per RFQ The module is an A/B slave type with ID/ID2 code A/E. No direct second-source cross-reference from other manufacturers — the AS-i profile is proprietary to the Siemens K60 family.","metaTitle":"Siemens 3RK2200-1DQ00-1AA3 Remote I/O Module, 8 Inputs, IP67","metaDescription":"Siemens 3RK2200-1DQ00-1AA3 K60 digital input module, 8 PNP inputs, 20-30 VDC, IP67. Active production, quoted to order against RFQ. Requires two AS-i addresses.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Remote I/O & Fieldbus Modules"],"specifications":{"Note":"module requires two addresses","Type":"8 inputs","Depth":"29 mm","PIN 1":"sensor supply L+","PIN 2":"data input II","PIN 3":"sensor supply L-","PIN 4":"data input I","PIN 5":"ground terminal","Width":"60 mm","title":"3RK2200-1DQ00-1AA3","Height":"152 mm","Socket":"PIN 4 = IN1 (D0) (addr. 1), PIN 2 = IN2 (D1) (addr. 1)","Socket 2":"PIN 4 = IN2 (D1) (addr. 1)","Socket 3":"PIN 4 = IN3 (D2) , PIN 2 = IN4 (D3)","Socket 4":"PIN 4 = IN4 (D3) (addr. 1)","Socket 5":"PIN 4 = IN1 (D0) (addr. 2), PIN 2 = IN2 (D1) (addr. 2)","Socket 6":"PIN4 = IN2 (D1) (addr. 2)","Socket 7":"PIN4 = IN3 (D2) (addr. 2), PIN2 = IN4 (D3) (addr. 2)","Socket 8":"PIN4 = IN4 (D3) (addr. 2)","Watchdog":"not required","Addressing":"front addressing socket","ID/ID2 code":"A/E","description":"AS-i compact module K60 digital A/B slave, 8 DI, IP67 8 x inputs, max. 2000 mA Sensor supply 24 V DC 8 x M12 socket Y-II assignment Mounting plate 3RK1901-0CA00 must be ordered separately","Delivery note":"the modules are delivered without mounting plate","Input Voltage":"20 ... 30 V","Input circuit":"PNP transistor","During Storage":"-40 ... +85 °C","Ground terminal":"PIN5 of each M12 socket is connected to the grounding wrist strap in the mounting plate using a pin","display of I/Os":"yellow LED","display of Uaux":"not required","lifecycle_stage":"current","During Operation":"-25 ... +85 °C","Fastening Method":"standard rail mounting/wall mounting using mounting plate for K60 compact module","Shock Resistance":"15g / 11 ms","I/O configuration":"0","Number I/O sockets":"8","protection class IP":"IP67","Design Of The Product":"digital I/O modules for operation in the field, IP67 - K60","For Signal <1> Minimum":"6 mA","With Signal <0> Maximum":"1.5 mA","Design Of The Slave Type":"A/B slave","Number Of Digital Inputs":"8","Number Of Digital Outputs":"0","Type Of Connection Technology":"2- and 3-wire technology","at ambient temperature 40 °C":"2 A","Inputs switching level High min":"10 V","sensor supply using AS-Interface":"short-circuit and overload resistant","display of AS-Interface/diagnostics":"green/red LED","AS interface total current input max":"45 mA","Outputs external power supply 24 V DC":"not required","Type Of Voltage Of The Input Voltages":"DC","Type Of Voltage Supply For Power Supply":"via AUX POWER","Design Of The Pin Assignment Of The Inputs":"Y-II assignement","Type Of Electrical Connection Of The Inputs And Outputs":"M12 screw-type terminals","operating voltage according to AS-Interface spezification":"26.5 ... 31.6 V","Property Of The Sensor Supply Short-Circuit And Overload Resistant":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/adaa87812618c195f74ff935e06d8d6f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=279799&mlfb=3RK2200-1DQ00-1AA3"},"ai":{"faq":[{"question":"What does 'module requires two addresses' mean for my AS-i network?","answer":"The module consumes two consecutive AS-i slave addresses to map all 8 inputs. Sockets 1-4 use address 1 (inputs D0-D3), sockets 5-8 use address 2 (inputs D0-D3). Your AS-i master must have two free addresses available in sequence."},{"question":"Can I use this module with NPN sensors?","answer":"No — the input circuit is PNP transistor only. The module expects sourcing sensors that switch the positive supply line to the input pin. NPN sinking sensors will not trigger the inputs."},{"question":"What compliance documentation does Siemens provide for 3RK2200-1DQ00-1AA3?","answer":"The module carries IP67 protection class and is designed for operation in the field. Standard Siemens documentation includes the declaration of conformity for CE marking; UL and other regional approvals are not listed in the available spec data."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK2200-1DQ00-1AA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK2200-1DQ00-1AA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}