{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK3141-1CD10","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK3141-1CD10","canonicalUrl":"https://aoctrl.com/siemens/3RK3141-1CD10","factsUrl":"https://aoctrl.com/api/mcp/products/3RK3141-1CD10","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RK3141-1CD10 PROFIsafe/ASIsafe F-Link, safety gateway, PROFIBUS, 124mm depth, 45mm width, IP20, snap-on DIN rail.","salesMarkdown":"The Siemens 3RK3141-1CD10 is a PROFIsafe/ASIsafe F-Link — a safety gateway that bridges a PROFIBUS DP network to an AS-Interface safety at work subnet. It's the part you drop into a control cabinet when you need to consolidate safe digital and analog I/O from an AS-i line into a PROFIBUS safety controller. Rated for safety category 4 per EN 954-1, it handles the highest-risk guarding applications — think press brakes, robot cells, or conveyor zones where a fault must stop the line in under the safe reaction time. At 45 mm wide and 124 mm deep, it fits a standard 4-module slot in a SIRIUS cabinet layout. ## What the key specs mean for a panel builder The 24 V DC supply feeds the gateway and the AS-i bus master; at 24 V with AS-i Power24V, the maximum current draw is 100 mA — light enough that you can daisy-chain power from an existing 24 V rail without a dedicated supply. PROFIBUS DP at its back end, AS-Interface on the field side. The gateway handles up to 31 AS-i slaves with a 5 ms cycle time, or 62 slaves at 10 ms. That makes it a good fit for medium-sized safety islands — not a full factory floor, but a single machine zone. Digital I/O data is mapped directly into the PROFIBUS process image; analog I/O is accessed via data record transfer. No extra memory mapping or function blocks needed on the PLC side — it's a straight drop into a standard safety program. IP20 protection class means it's for the cabinet, not the field. Keep it behind a gland plate or inside an enclosure rated for the environment.","metaTitle":"Siemens 3RK3141-1CD10 PROFIsafe/ASIsafe F-Link, 124mm depth,","metaDescription":"Siemens 3RK3141-1CD10 PROFIsafe/ASIsafe F-Link. Safety gateway with PROFIsafe & ASIsafe protocols. IP20, 124mm depth, snap-on DIN rail. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Safety Relays"],"specifications":{"SNMP":"No","Depth":"124mm","Other":"0","Width":"45mm","title":"3RK3141-1CD10","EEx ia":"No","EEx ib":"No","Height":"111mm","TCP/IP":"No","description":"DP/AS-Interface F-Link. gateway PROFIBUS DP/AS-i for safety-oriented data transmission from ASIsafe to PROFIBUS-DP-PROFIsafe. Master profile M3/M4 according to AS-i specification V3.0. degree of protection IP20. screw terminals","For 31 Slaves":"5ms","For 62 Slaves":"10ms","Module Format":"IP20","During Storage":"-40 ... +85°C","power loss [W]":"3W","as AS-Interface":"1","lifecycle_stage":"current","During Transport":"-40 ... +85°C","Fastening Method":"snap-on fastening on 35 mm DIN rail or screw fastening using an additional push-in lug","according to USB":"0","PROFIBUS protocol":"Yes","Galvanic Isolation":"Yes","PROFIsafe protocol":"Yes","Product Designation":"PROFIsafe/ASIsafe F-Link","according to RS 485":"1","protection class IP":"IP20","PROFINET IO protocol":"No","Web-Based Management":"No","According To Wireless":"0","Diagnostics Via Email":"No","PROFINET CBA protocol":"No","according to PROFINET":"0","Type Of Voltage Supply":"via 24 V DC","as status display by LED":"DEVICE, ASi, BF, SF","Type Of Data Transmission":"PROFIBUS","access to analog I/O data":"via process diagram/peripheral addresses and data record transfer","access to digital I/O data":"via process image/peripheral addresses","Insulation Voltage Rated Value":"500V","category according to EN 954-1":"4","according to Industrial Ethernet":"0","ASIsafe (Safety at work) protocol":"Yes","at 24 V with AS-i Power24V maximum":"100mA","Product Component Optical Interface":"No","As Status Indication Through Display":"Dot-matrix display, 2-line","Product Feature Redundancy Capability":"No","AS-Interface master profile is supported":"M4 (in acc. with AS-interface specification V 3.0)","If Installed On Horizontal Mounting Rail":"0 ... 50°C","number of inputs for AS-Interface maximum":"496","type of configuration of the AS-Interface":"Set pushbutton on device, STEP7, GSD, command interface","number of outputs for AS-Interface maximum":"496","requirement class according to DIN V 19250":"AK7, AK8","Suitability For Use Safety-Related Function":"Yes","product function suitable for AS-i Power24V":"No","number of AS-i slaves per AS-Interface maximum":"62","operating condition separate power supply 24 V":"Yes","standard for wireless communication IEEE 802.11":"No","SIL Claim Limit (subsystem) according to EN 62061":"3","type of electrical connection of the AS-Interface":"Screw-type connection","performance level (PL) according to EN ISO 13849-1":"e","relative humidity at 25 °C during operation maximum":"95%","Installation Altitude At Height Above Sea Level Maximum":"2 000m"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,143.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/48c3e7f2d466ba66bb52814affd61d2b.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=307615&mlfb=3RK3141-1CD10"},"ai":{"faq":[{"question":"Does the 3RK3141-1CD10 support PROFIsafe?","answer":"Yes, it supports both PROFIsafe and ASIsafe (Safety at work) protocols, bridging a PROFIBUS safety controller to an AS-i safety subnet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK3141-1CD10","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK3141-1CD10 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}