{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK4320-3EQ54-1BA3","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK4320-3EQ54-1BA3","canonicalUrl":"https://aoctrl.com/siemens/3RK4320-3EQ54-1BA3","factsUrl":"https://aoctrl.com/api/mcp/products/3RK4320-3EQ54-1BA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RK4320-3EQ54-1BA3, AS-Interface reversing motor starter, 1.6 A at 400 V AC-3, CLASS 10, IP54, 24 V DC control, 205 × 245 × 215 mm.","salesMarkdown":"## What this SIRIUS reversing starter fits The 3RK4320-3EQ54-1BA3 is a Siemens SIRIUS motor starter MCU designed for AS-Interface bus communication — it handles reversing motor control with integrated short-circuit protection and a brake output for 400 V AC brakes. The enclosure measures 205 mm deep by 245 mm wide by 215 mm tall, IP54 rated for dust and splash resistance — suitable for panel-mount in washdown-adjacent areas, not direct hose-down zones. ## Mounting and integration notes Mounts on a vertical surface with ±180° rotation possible; can also be tilted forward or backward by ±22.5° on a vertical surface — gives some flexibility for cable entry orientation in crowded panels. Control supply is 24 V DC nominal (20.4 to 26.4 V DC range), and the unit draws its bus power from the AS-Interface network — two digital inputs are onboard for local sensors or pushbuttons. Ambient operating range -25 to +50 °C; the bimetal overload is self-powered and doesn't add heat load to the panel at rated current.","metaTitle":"Siemens 3RK4320-3EQ54-1BA3 AS-Interface Motor Starter, 1.6 A","metaDescription":"Siemens SIRIUS reversing motor starter, 1.6 A at 400 V AC-3, CLASS 10 trip, IP54, AS-Interface bus, 24 V DC control. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"205 mm","Width":"245 mm","title":"3RK4320-3EQ54-1BA3","Height":"215 mm","Trip Class":"CLASS 10","description":"SIRIUS MCU motor starter Enclosure degree of protection IP54 metal Communication AS-Interface electromechanically switching Short-circuit protection with circuit breaker Reversing starter Brake 400 V AC (internal) Performance class 1.60 A Motor circuit breaker with bi-metal thermal Rotary operating mechanism gray/black Connection power M screw connection Standard product","Type Of Voltage":"DC","lifecycle_stage":"current","Bus Communication":"Yes","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","PROFINET protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Product Designation":"motor starter MCU for AS-Interface","protection class IP":"IP54","PROFIBUS DP protocol":"No","Design Of The Product":"reversing starter","Number Of Digital Inputs":"2","Short Circuit Protection":"Yes","at AC at 400 V rated value":"1.6 A","brake control with 24 V DC":"No","Operating Frequency Minimum":"80 1/h","brake control with 180 V DC":"No","brake control with 400 V AC":"Yes","brake control with 500 V DC":"No","Type Of The Motor Protection":"bimetal","at AC-3 at 400 V rated value":"1.6 A","Operating Voltage Rated Value":"340 ... 440 V","Substance Prohibitance (Date)":"05/01/2012","Design Of The Switching Contact":"electromechanical","Operating Frequency 1 Rated Value":"50 Hz","Operating Frequency 2 Rated Value":"60 Hz","Design Of Short-Circuit Protection":"circuit-breakers","Ambient Temperature During Operation":"-25 ... +50 °C","Product Component Motor Brake Output":"Yes","Type Of Voltage Of The Supply Voltage":"DC","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 26.4 V","with low demand rate according to SN 31920":"50 %","protocol is supported AS-Interface protocol":"Yes","with high demand rate according to SN 31920":"75 %","operating power at AC-3 at 400 V rated value":"0.6 kW","Product Extension Braking Module For Brake Control":"No","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","maximum short-circuit current breaking capacity (Icu) at 400 V rated value":"50 000 A","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"1.1 ... 1.6 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b5de291052c20fceed06e6d8c53e7ff0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=490027&mlfb=3RK4320-3EQ54-1BA3"},"ai":{"faq":[{"question":"What AS-Interface protocol does the 3RK4320-3EQ54-1BA3 support?","answer":"It supports the AS-Interface protocol for bus communication — no PROFIBUS DP or PROFINET onboard. The unit communicates over the AS-i flat cable for both control and power."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK4320-3EQ54-1BA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK4320-3EQ54-1BA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}