{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK4340-3AR51-1BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK4340-3AR51-1BA0","canonicalUrl":"https://aoctrl.com/siemens/3RK4340-3AR51-1BA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK4340-3AR51-1BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RK4340-3AR51-1BA0, motor starter MCU, I/O controlled, reversing starter, 0.63 A at AC-3 400 V, IP55, Class 10.","salesMarkdown":"## SIRIUS MCU reversing starter, I/O controlled Enclosure is IP55, so the unit is dust-protected and can handle water jets from any direction — suitable for installation in washdown areas or outdoor cabinets where the starter is exposed to hose-down cleaning. The operating voltage range is 340 to 440 V AC, covering 400 V nominal systems with tolerance. ## Control supply and fieldbus note Control supply voltage is 20.4 to 26.4 V DC, so you need a 24 V DC power supply in the panel — no AC control voltage option here. The unit has no digital inputs onboard (0 digital inputs), which means the I/O control signal comes from an external controller or PLC via hardwired connections. There is no PROFIBUS DP, no PROFINET, no AS-Interface, and no bus communication support on this variant — it's a pure hardwired I/O reversing starter. If you need fieldbus integration, you'd look at a different SIRIUS MCU order code with the communication module built in.","metaTitle":"Siemens 3RK4340-3AR51-1BA0 SIRIUS MCU Reversing Starter","metaDescription":"Siemens SIRIUS 3RK4340-3AR51-1BA0 motor starter MCU, reversing starter, 0.63 A at AC-3 400 V, IP55, Class 10. Current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"145 mm","Width":"182 mm","title":"3RK4340-3AR51-1BA0","Height":"220 mm","Trip Class":"CLASS 10","description":"SIRIUS MCU motor starter Enclosure degree of protection IP55 plastic Communication without electromechanically switching Short-circuit protection with circuit breaker Reversing starter Brake without Performance class 0.63 A Motor circuit breaker with bi-metal thermal Manual operation without Connection power M screw connection Standard product","Type Of Voltage":"DC","lifecycle_stage":"current","Bus Communication":"No","Mounting Position":"+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface","PROFINET protocol":"No","Product Brand Name":"SIRIUS","Type Of Assignment":"1","Product Designation":"motor starter MCU, I/O controlled","protection class IP":"IP55","PROFIBUS DP protocol":"No","Design Of The Product":"reversing starter","Number Of Digital Inputs":"0","Short Circuit Protection":"Yes","at AC at 400 V rated value":"0.63 A","brake control with 24 V DC":"No","Operating Frequency Minimum":"80 1/h","brake control with 180 V DC":"No","brake control with 400 V AC":"No","brake control with 500 V DC":"No","Type Of The Motor Protection":"bimetal","at AC-3 at 400 V rated value":"0.63 A","Operating Voltage Rated Value":"340 ... 440 V","Substance Prohibitance (Date)":"05/01/2012","Design Of The Switching Contact":"electromechanical","Operating Frequency 1 Rated Value":"50 Hz","Operating Frequency 2 Rated Value":"60 Hz","Design Of Short-Circuit Protection":"circuit-breakers","Ambient Temperature During Operation":"-25 ... +35 °C","Product Component Motor Brake Output":"No","Type Of Voltage Of The Supply Voltage":"DC","reference code according to IEC 81346-2":"Q","Number Of Poles For Main Current Circuit":"3","control supply voltage at DC rated value":"20.4 ... 26.4 V","with low demand rate according to SN 31920":"50 %","protocol is supported AS-Interface protocol":"No","with high demand rate according to SN 31920":"75 %","operating power at AC-3 at 400 V rated value":"0.2 kW","Product Extension Braking Module For Brake Control":"No","Relative Negative Tolerance Of The Operating Frequency":"-10 %","Relative Positive Tolerance Of The Operating Frequency":"10 %","Type Of Electrical Connection For Main Current Circuit":"screw-type terminals","breaking capacity maximum short-circuit current (Icu) at 400 V rated value":"50 000 A","Adjustable Current Response Value Current Of The Current-Dependent Overload Release":"0.45 ... 0.63 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ae85272a3156700a6c344ba7b17ad509.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=392330&mlfb=3RK4340-3AR51-1BA0"},"ai":{"faq":[{"question":"Is 3RK4340-3AR51-1BA0 a reversing starter?","answer":"Yes, the product design is specifically a reversing starter. That means it has two contactors mechanically interlocked to reverse the phase sequence to the motor, allowing forward and reverse operation from a single device. It's part of the SIRIUS MCU family of motor starters."},{"question":"Does 3RK4340-3AR51-1BA0 have PROFIBUS or PROFINET?","answer":"No. This variant does not support PROFIBUS DP, PROFINET, or AS-Interface. It has no bus communication capability at all — it's a pure I/O-controlled reversing starter. The control signal comes via hardwired I/O from an external controller."},{"question":"Where can I buy 3RK4340-3AR51-1BA0?","answer":"This part is sourced to order against an RFQ. Availability and pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK4340-3AR51-1BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK4340-3AR51-1BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}