{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RK5010-0CA00-0AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RK5010-0CA00-0AA0","canonicalUrl":"https://aoctrl.com/siemens/3RK5010-0CA00-0AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RK5010-0CA00-0AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 3RK5010-0CA00-0AA0 IO-Link module K20, 8 digital inputs, 400 mA maximum, IP67, 45 mm depth, 20 mm width, 164 mm height.","salesMarkdown":"## Eight digital inputs in an IP67 slice The 3RK5010-0CA00-0AA0 is an IO-Link module K20 that provides 8 digital inputs, each configurable with adjustable input delay times of 1 ms, 3 ms, 15 ms, or 20 ms per module. Rated for a maximum of 400 mA, it operates on a 24 V DC supply (18 V minimum, 30 V maximum) and carries IP67 protection, meaning it withstands washdown environments without an additional enclosure. Mounting is via frontal or lateral wall mounting — the 20 mm width and 45 mm depth fit into tight panel layouts or machine-mount applications. ## Pinout and sensor supply per socket Each of the eight M12 sockets provides sensor supply + on PIN 1, sensor supply - on PIN 3, and the digital input signal on PIN 4 — a standard three-wire sensor interface.","metaTitle":"Siemens 3RK5010-0CA00-0AA0 IO-Link Module K20, 8 Inputs","metaDescription":"Siemens 3RK5010-0CA00-0AA0 IO-Link module K20 with 8 digital inputs, 400 mA max, IP67. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Motor Starters"],"specifications":{"Depth":"45mm","Width":"20mm","title":"3RK5010-0CA00-0AA0","Height":"164mm","Maximum":"400mA","description":"!!! phased-out product!!! The preferred successor is 6ES7141-5BF00-0BL0 IO-Link module K20, digital 8 DI, IP67, 8x 1 input sensor supply max. 400 mA 8x M8 socket standard assignment","During Storage":"-40 ... +85°C","lifecycle_stage":"current","During Operation":"-25 ... +70°C","Fastening Method":"frontal or lateral wall mounting","1 at DC rated value":"24V","Maximum Permissible":"30V","Minimum Permissible":"18V","Product Designation":"IO-Link module K20","protection class IP":"IP67","of socket 1 at PIN 1":"sensor supply +","of socket 1 at PIN 3":"sensor supply -","of socket 1 at PIN 4":"IN1","of socket 2 at PIN 1":"sensor supply +","of socket 2 at PIN 3":"sensor supply -","of socket 2 at PIN 4":"IN2","of socket 3 at PIN 1":"sensor supply +","of socket 3 at PIN 3":"sensor supply -","of socket 3 at PIN 4":"IN3","of socket 4 at PIN 1":"sensor supply +","of socket 4 at PIN 3":"sensor supply -","of socket 4 at PIN 4":"IN4","of socket 5 at PIN 1":"sensor supply +","of socket 5 at PIN 3":"sensor supply -","of socket 5 at PIN 4":"IN5","of socket 6 at PIN 1":"sensor supply +","of socket 6 at PIN 3":"sensor supply -","of socket 6 at PIN 4":"IN6","of socket 7 at PIN 1":"sensor supply +","of socket 7 at PIN 3":"sensor supply -","of socket 7 at PIN 4":"IN7","of socket 8 at PIN 1":"sensor supply +","of socket 8 at PIN 3":"sensor supply -","of socket 8 at PIN 4":"IN8","Design Of The Product":"8 digital inputs","Of The Input Delay Time":"adjustable for each module (1 ms, 3 ms, 15 ms, 20 ms)","Number Of Digital Inputs":"8","Of Socket 1 To 4 Maximum":"200mA","Of Socket 5 To 8 Maximum":"200mA","Number Of Digital Outputs":"0","Number Of Input/Output Sockets":"8","Of The Inverting Of The Input Signal":"adjustable for each input","EMC immunity according to IEC 60947-1":"ambience A (industrial sector)","Type Of Voltage Of The Supply Voltage":"DC","reference code according to EN 61346-2":"K","As Status Display Of The Inputs/Outputs":"green LED for each channel","Initial Value For Signal<1>-Recognition":"11mA","Design Of The Pin Assignment Of The Inputs":"standard assignement","Full-Scale Value For Signal<0> Recognition":"1.5mA","As Status Display Of The Input/Output Link Device":"green/red dual LED","EMC emitted interference according to IEC 60947-1":"CISPR11, ambience A (industrial sector)","Evaluable Diagnostic Message Via Input/Output Link":"overload/short-circuit sensor supply, internal error","Type Of Voltage Supply Via Input/Output Link Master":"Yes","Installation Altitude At Height Above Sea Level Maximum":"4 000m","product function control circuit interface with IO link":"Yes","As Status Display Of The Input/Output Link Communication":"green/red dual LED","Input Voltage At Digital Input 1 Initial Value For Signal<1>-Recognition":"10V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f71b52aa90dec070141af7f9cccf5876.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=410054&mlfb=3RK5010-0CA00-0AA0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RK5010-0CA00-0AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RK5010-0CA00-0AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}