{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RN2013-1GW30","brand":"Siemens","brandSlug":"siemens","productSlug":"3RN2013-1GW30","canonicalUrl":"https://aoctrl.com/siemens/3RN2013-1GW30","factsUrl":"https://aoctrl.com/api/mcp/products/3RN2013-1GW30","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RN2 thermistor motor protection relay, 3RN2013-1GW30, 24-240 VAC/DC, IP20, ATEX approved, MTBF 97 a.","salesMarkdown":"The Siemens 3RN2013-1GW30 is a SIRIUS 3RN2 thermistor motor protection relay — a standard evaluation unit with ATEX approval, open-circuit and short-circuit detection in the sensor circuit, safe disconnection, and non-volatile error memory. It's designed to protect motors by monitoring PTC thermistor sensors embedded in the windings. The relay trips when the winding temperature exceeds the sensor's threshold, preventing thermal damage. Rated supply voltage covers 24 to 240 VAC/DC at 50/60 Hz, making it usable across most industrial control voltages without a separate power supply module. The relay's MTBF is 97 a and MTTFd is 303 a, reflecting a design suited for continuous-duty applications where unplanned downtime is costly. IP20 protection means it's for use inside a panel enclosure, not in wet or dusty environments. Pollution degree 3 suits industrial atmospheres with conductive or dry non-conductive pollution. The relay accepts solid and stranded conductors 20–12 AWG (1x 20–12, 2x 20–14 for solid), with a strip length matching standard terminal blocks. The 90 mm depth leaves clearance for wiring ducts and adjacent components. Output contacts are rated 1 A at 24 V, 0.2 A at 125 V, and 0.1 A at 250 V — these are the switching currents for the relay's output, not motor load currents. The relay signals a PLC or contactor coil; it does not switch motor power directly. The relay carries ATEX approval for use in potentially explosive atmospheres, with open-circuit and short-circuit detection in the sensor circuit and safe disconnection. The standard evaluation unit includes non-volatile error memory and auto-reset capability. External reset is supported. The display version has an LED for status indication.","metaTitle":"Siemens 3RN2013-1GW30 SIRIUS thermistor motor protection rel","metaDescription":"Siemens 3RN2013-1GW30 SIRIUS thermistor motor protection relay, 24-240 VAC/DC, IP20, ATEX approved, MTBF 97 a. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Process / Temperature Controllers"],"specifications":{"MTBF":"97 a","Depth":"90 mm","MTTFd":"303 a","Solid":"20 ... 12","Width":"22.5 mm","Height":"100 mm","Upwards":"0 mm","at 24 V":"1 A","Forwards":"0 mm","Stranded":"20 ... 12","at 125 V":"0.2 A","at 240 V":"0.2 ms","at 250 V":"0.1 A","Backwards":"0 mm","Downwards":"0 mm","auto-RESET":"Yes","At The Side":"0 mm","Rated Value":"24 ... 240 V","Error Memory":"Yes","Initial Value":"0.85","During Storage":"-40 ... +85 °C","External Reset":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +85 °C","Fastening Method":"screw and snap-on mounting onto 35 mm DIN rail","Full-Scale Value":"1.1","Product Category":"SIRIUS 3RN2 thermistor motor protection","Product Function":"thermistor motor protection","Mounting Position":"any","Product Brand Name":"SIRIUS","Between The Outputs":"Yes","Degree Of Pollution":"3","Product Designation":"Thermistor motor protection relay","display version LED":"Yes","protection class IP":"IP20","at 50 Hz rated value":"24 ... 240 V","at 60 Hz rated value":"24 ... 240 V","for AWG cables solid":"1x (20 ... 12), 2x (20 ... 14)","Design Of The Product":"Standard evaluation unit with ATEX approval, open-circuit and short-circuit detection in the sensor circuit, safe disconnection, non-volatile","Between Input And Output":"Yes","Relative Metering Precision":"2 %","Safe failure fraction (SFF)":"74 %","Substance Prohibitance (Date)":"05/28/2009","Type Of Electrical Connection":"screw-type terminals","Dynamic Open-Circuit Detection":"Yes","Material Of Switching Contacts":"AgSnO2 hard gold-plated","Operating Frequency Rated Value":"50 ... 60 Hz","For Auxiliary And Control Circuit":"screw-type terminals","Design Of The Electrical Isolation":"Protective separation","Relative Humidity During Operation":"70 %","Surge Voltage Resistance Rated Value":"6 kV","category according to EN ISO 13849-1":"1","Between Control And Auxiliary Circuit":"300 V","Explosion Protection Category For Gas":"[Ex e] [Ex d] [Ex px]","Explosion Protection Category For Dust":"[Ex t] [Ex p]","Between Auxiliary And Auxiliary Circuit":"300 V","due to burst according to IEC 61000-4-4":"2 kV (power ports) / 1 kV (signal ports)","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"0.5 ... 4 mm²","average diagnostic coverage level (DCavg)":"18 %","Tightening Torque With Screw-Type Terminals":"0.6 ... 0.8 N·m","number of CO contacts for auxiliary contacts":"2","number of NC contacts for auxiliary contacts":"0","number of NO contacts for auxiliary contacts":"0","shock resistance according to IEC 60068-2-27":"11g / 15 ms","Between The Voltage Supply And Other Circuits":"Yes","Type Of Voltage Of The Control Supply Voltage":"AC/DC","hardware fault tolerance according to IEC 61508":"0","vibration resistance according to IEC 60068-2-6":"10 ... 55 Hz: 0.35 mm","PFHD with high demand rate according to EN 62061":"3.76E-7 1/h","At Rate Of Recognizable Hazardous Failures (λDd)":"6.8E-8 1/h","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","PFDavg with low demand rate according to IEC 61508":"0.0041","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","performance level (PL) according to EN ISO 13849-1":"c","Buffering Time In The Event Of Power Failure Minimum":"40 ms","At Rate Of Non-Recognizable Hazardous Failures (λDu)":"3.08E-7 1/h","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Thermal Current Of The Switching Element With Contacts Maximum":"5 A","continuous current of the DIAZED fuse link of the output relay":"6 A","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/3RN2013-1GW30/alternatives.json"},"ai":{"faq":[{"question":"What is the MTBF of 3RN2013-1GW30?","answer":"The listed MTBF is 97 a, with MTTFd at 303 a."},{"question":"What is the depth of 3RN2013-1GW30?","answer":"The depth is 90 mm."},{"question":"What compliance documentation does Siemens provide for 3RN2013-1GW30?","answer":"The relay carries ATEX approval for explosive atmospheres. Standard Siemens documentation includes the declaration of conformity for CE, RoHS, and REACH. Specific certificates are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RN2013-1GW30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RN2013-1GW30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}