{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RP1527-2EC30","brand":"Siemens","brandSlug":"siemens","productSlug":"3RP1527-2EC30","canonicalUrl":"https://aoctrl.com/siemens/3RP1527-2EC30","factsUrl":"https://aoctrl.com/api/mcp/products/3RP1527-2EC30","rawCanonicalId":null},"summary":{"shortDescription":"Timing relay, Phased-out product!!! For further information, please contact our sales department ansprechverzögert 1 NO contact (semiconductor) 4 time ranges, 0.05 s....240 s 24...66 V AC/DC, 2-wire spring-type terminals","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Time Delay Relays"],"specifications":{"Depth":"91 mm","Solid":"24 ... 16","Width":"22.5 mm","at DC":"24 ... 66 V","Height":"84 mm","Upwards":"0 mm","Forwards":"0 mm","ON-delay":"Yes","Stranded":"24 ... 16","at 50 Hz":"24 ... 66 V","at 60 Hz":"24 ... 66 V","Backwards":"0 mm","Downwards":"0 mm","OFF delay":"No","At The Side":"0 mm","Non-Volatile":"No","Relay Output":"No","Initial Value":"0.85","Pulse Delayed":"No","Pulse-Shaping":"No","Recovery Time":"50 ms","During Storage":"-40 ... +85 °C","Adjustable Time":"0.05 ... 240 s","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +85 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail","Full-Scale Value":"1.1","Delayed Switching":"0","Mounting Position":"any","additive ON-delay":"No","Product Brand Name":"SIRIUS","Star-Delta Circuit":"No","Type Of Insulation":"Basic insulation","Degree Of Pollution":"3","Product Designation":"timing relay","at AWG cables solid":"2x (24 ... 16)","protection class IP":"IP20","Passing Make Contact":"No","Instantaneous Contact":"0","Passing Break Contact":"No","Semi-Conductor Output":"Yes","Power Supply Influence":"±1 %","at AWG cables stranded":"2x (24 ... 16)","power loss [W] maximum":"1 W","OFF delay/instantaneous":"No","Relative Repeat Accuracy":"1 %","Residual Current Maximum":"5 mA","Pulse Delayed/Instantaneous":"No","Pulse-Shaping/Instantaneous":"No","Substance Prohibitance (Date)":"05/28/2009","ON-delay/instantaneous contact":"No","additive ON-delay/instantaneous":"No","ON-delay/OFF-delay/instantaneous":"No","Control Supply Voltage Frequency 1":"50 ... 60 Hz","Relative Humidity During Operation":"10 ... 95 %","Star-Delta Circuit With Delay Time":"No","Passing Break Contact/Instantaneous":"No","Surge Voltage Resistance Rated Value":"4 000 V","EMC immunity according to IEC 61812-1":"EN 61000-6-2","Flashing Symmetrically With Pulse Start":"No","due to burst according to IEC 61000-4-4":"2 kV network connection / 1 kV control connection","reference code according to IEC 81346-2":"K","Finely Stranded With Core End Processing":"0.3 ... 1.5 mm²","Flashing Asymmetrically With Pulse Start":"No","Influence Of The Surrounding Temperature":"±5 %","Product Extension Optional Remote Control":"No","Product Extension Required Remote Control":"No","Flashing Symmetrically With Interval Start":"No","Passing Make Contact/Instantaneous Contact":"No","Finely Stranded Without Core End Processing":"0.3 ... 1.5 mm²","Flashing Asymmetrically With Interval Start":"No","shock resistance according to IEC 60068-2-27":"11g / 15 ms","Retriggerable With Deactivated Control Signal":"No","Type Of Voltage Of The Control Supply Voltage":"AC/DC","Switching Capacity Current With Inductive Load":"0.01 ... 0.6 A","operating frequency with 3RT2 contactor maximum":"5 000 1/h","vibration resistance according to IEC 60068-2-6":"10 ... 55 Hz / 0.35 mm","Retrotriggerable With Switched-On Control Signal":"No","EMC emitted interference according to IEC 61812-1":"EN 61000-6-4(3)","Mechanical Service Life (Switching Cycles) Typical":"100 000 000","electrostatic discharge according to IEC 61000-4-2":"4 kV contact discharge / 8 kV air discharge","Flashing Symmetrically With Pulse Start/Instantaneous":"No","Relative Setting Accuracy Relating To Full-Scale Value":"5 %","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Flashing Symmetrically With Interval Start/Instantaneous":"No","Type Of Electrical Connection For Auxiliary And Control Circuit":"spring-loaded terminals","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","Retrotriggerable With Deactivated Control Signal/Instantaneous Contact":"No","Retrotriggerable With Switched-On Control Signal/Instantaneous Contact":"No"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$58.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3add86feea20ffc7e57bb93e4fcd5f3a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=15104&mlfb=3RP1527-2EC30"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RP1527-2EC30","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RP1527-2EC30 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}