{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RS7005-2KW00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RS7005-2KW00","canonicalUrl":"https://aoctrl.com/siemens/3RS7005-2KW00","factsUrl":"https://aoctrl.com/api/mcp/products/3RS7005-2KW00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RS7005-2KW00 multi-range signal converter, active switchable, 1 channel, 24-240 V AC/DC supply, 0-10 V / 0-20 mA / 4-20 mA input, frequency output up to 10 kHz, snap-on 17.5 mm width, IP20.","salesMarkdown":"The Siemens 3RS7005-2KW00 is a SIRIUS multi-range signal converter — an active, switchable device that takes a 0-10 V, 0-20 mA, or 4-20 mA input and converts it to a frequency output selectable at 0-50 Hz, 0-100 Hz, 0-1 kHz, or 0-10 kHz. It runs on a universal 24-240 V AC/DC supply, draws 0.34 W, and snaps onto a DIN rail at 17.5 mm wide — a single-width module that fits tight panel layouts without side clearances. The input accepts three common industrial analog signals — 0-10 V, 0-20 mA, and 4-20 mA — so it interfaces directly with most PLC analog output cards, pressure transmitters, or temperature transducers without external signal conditioning. The output is a frequency signal, not a voltage or current loop, which means it drives frequency-input devices like speed displays, counters, or frequency-to-analog converters downstream. The 0.015 %/°C temperature drift means the conversion accuracy holds tight across a panel's thermal cycle; at a 40 °C swing the drift is under 0.6 % of span. The 17.5 mm width and snap-on mounting mean it occupies one standard DIN-rail position — no extra space needed above, below, or to the sides (all clearances are 0 mm). Signal converters like this one sit between an analog sensor or controller output and a device that expects a frequency input — for example, converting a 4-20 mA flow transmitter signal to a 0-1 kHz pulse train for a remote totalizer, or translating a 0-10 V speed reference from a PLC into a 0-50 Hz signal for a variable-frequency drive that accepts frequency setpoints. The universal AC/DC supply means it works in both 24 VDC control panels and 230 VAC distribution panels without a separate power supply module.","metaTitle":"Siemens 3RS7005-2KW00 SIRIUS signal converter, 24-240 VAC/DC","metaDescription":"Siemens 3RS7005-2KW00 SIRIUS multi-range signal converter. Active, switchable design. Input 0-10 V, 0-20 mA, 4-20 mA; output 0-50 Hz to 0-10 kHz. Snap-on DIN rail, IP20, current li","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Time Delay Relays"],"specifications":{"Depth":"72.5 mm","Solid":"20 ... 14","Width":"17.5 mm","at DC":"0.8 ... 1.1","title":"3RS7005-2KW00","Height":"93 mm","Upwards":"0 mm","Forwards":"0 mm","Stranded":"20 ... 14","Backwards":"0 mm","Downwards":"0 mm","At The Side":"0 mm","description":"Signal converter 24-240 V AC/DC, 3-way separation Input: 0-10 V, 0/4 - 20 mA; Output: 0-50/100 Hz/1/10 kHz; Spring-type terminal (push-in)","Input Voltage":"30 V","During Storage":"-40 ... +80 °C","at AC at 50 Hz":"0.8 ... 1.1","at AC at 60 Hz":"0.8 ... 1.1","Limit Frequency":"30 Hz","Type Of Voltage":"AC/DC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"snap-on mounting","Product Category":"Signal converter","Mounting Position":"any","Between The Inputs":"No","Number Of Channels":"1","Product Brand Name":"SIRIUS","Between The Outputs":"No","Product Designation":"multi-range converters","at AWG cables solid":"1 x (20 ... 14)","display version LED":"Yes","protection class IP":"IP20","at 50 Hz rated value":"24 ... 240 V","at 60 Hz rated value":"24 ... 240 V","Consumed Active Power":"0.34 W","Design Of The Product":"active, switchable","at AWG cables stranded":"1x (20 ... 14)","Type Of Signal At Input":"0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA","Between Input And Output":"Yes","Type Of Signal At Output":"0 ... 50 Hz, 0 ... 100 Hz, 0 ... 1 kHz, 0 ... 10 kHz","temperature drift per °C":"0.015 %/°C","Relative Metering Precision":"0.1 %","Relative Linearity Deviation":"0.05 %","Substance Prohibitance (Date)":"03/25/2015","Type Of Electrical Connection":"spring-loaded terminals","supply voltage at DC rated value":"24 ... 240 V","Design Of The Electrical Isolation":"3 paths","Relative Humidity During Operation":"10 ... 95 %","Supply Voltage Frequency Rated Value":"60 ... 50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","due to burst according to IEC 61000-4-4":"1 kV 5/50 ns","reference code according to IEC 81346-2":"T","Finely Stranded With Core End Processing":"0.25 ... 1.5 mm²","Input Impedance Of Current Input Maximum":"100 Ω","Input Impedance Of Voltage Input Minimum":"330 kΩ","Property Of The Output Short-Circuit Proof":"Yes","Finely Stranded Without Core End Processing":"0.25 ... 2.5 mm²","shock resistance according to IEC 60068-2-27":"sinusoidal half-wave 15g / 11 ms","Between The Voltage Supply And Other Circuits":"Yes","vibration resistance according to IEC 60068-2-6":"6 ... 150 Hz: 2 g","EMC emitted interference according to IEC 60947-1":"Environment B","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Installation Altitude At Height Above Sea Level Maximum":"2 000 m"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$614.74","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7872a89b9f6bc991b2b013db0a2ac31e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=567463&mlfb=3RS7005-2KW00"},"ai":{"faq":[{"question":"What is the depth of the 3RS7005-2KW00?","answer":"The depth is 72.5 mm. Combined with a width of 17.5 mm and height of 93 mm, it occupies a single DIN-rail module with zero clearance required on any side."},{"question":"What wire sizes does the 3RS7005-2KW00 accept?","answer":"It accepts solid or stranded conductors from 20 AWG to 14 AWG (1 x 20...14 AWG per terminal)."},{"question":"What input and output signal types does it support?","answer":"Input: 0-10 V, 0-20 mA, or 4-20 mA. Output: selectable frequency ranges of 0-50 Hz, 0-100 Hz, 0-1 kHz, or 0-10 kHz."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RS7005-2KW00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RS7005-2KW00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}