{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RS7006-2FE00","brand":"Siemens","brandSlug":"siemens","productSlug":"3RS7006-2FE00","canonicalUrl":"https://aoctrl.com/siemens/3RS7006-2FE00","factsUrl":"https://aoctrl.com/api/mcp/products/3RS7006-2FE00","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RS7006-2FE00, universal signal converter, 1 channel, 17.5 mm width, snap-on mounting, IP20.","salesMarkdown":"The Siemens SIRIUS 3RS7006-2FE00 is a universal signal converter, one channel, designed to accept a wide range of analog inputs — from 0...60 mV up to 0...20 V, and current loops including 4...20 mA, 0...20 mA, and ±20 mA. It's an active, switchable design, meaning you can configure it for the signal type you're dealing with in the field. That single channel handles one process variable at a time, so for a multi-loop skid you'd stack them — each one takes up 17.5 mm of DIN rail, which is a standard single-module slice. It's part of the SIRIUS family, Siemens' industrial-control component line for panel building. The input voltage rating is 30 V AC/DC, and the converter draws only 0.5 W of active power. That low draw means you can power it from a small 24 V supply without worrying about the heat budget in a crowded enclosure — 0.5 W is negligible for a panel with a few relays and a PLC. The 20 mV maximum voltage ripple on the supply tells you this converter is sensitive to a clean DC rail; if your 24 V bus has a noisy VFD on it, you'll want to check the ripple before blaming the signal converter for a drifting 4-20 mA loop. Galvanic isolation between input and output is present, which is the main reason you'd reach for this box over a simple resistor shunt. That isolation breaks ground loops between the field transmitter and the PLC analog input card — a common source of offset error in long cable runs. No isolation between the two inputs (there's only one channel) or between the two outputs, so don't expect channel-to-channel separation on a multi-unit install. The rise time is 6 ms, and the limit frequency is 30 Hz. That's fine for a temperature or pressure trend, but too slow for a fast-acting flow or vibration signal. If you're converting a 4-20 mA from a magnetic flowmeter with a 100 Hz output, this converter will low-pass it — you'll lose the peaks. The 30 Hz limit is the bandwidth of the converter itself, not the input signal's carrier. The 17.5 mm width is the standard single-module footprint — one slot in a SIRIUS or SENTRON distribution block row. Clearances are zero all around — 0 mm upwards, downwards, forwards, backwards, and to the side — meaning you can butt it against the next component without derating for heat or creepage. Wiring is via screw terminals accepting 20...14 AWG solid or stranded, one conductor per clamp. The IP20 protection class means it's for use inside a closed panel only — no washdown, no dust. If you need to mount it in a field enclosure that sees condensation, you'll want a cover or a higher-rated enclosure around it.","metaTitle":"Siemens SIRIUS 3RS7006-2FE00 Universal Signal Converter, 1-C","metaDescription":"Siemens SIRIUS universal signal converter 3RS7006-2FE00, 1 channel, 17.5mm wide, snap-on DIN rail. Accepts mV, V, mA inputs. In current production. Source to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Time Delay Relays"],"specifications":{"Depth":"72.5 mm","Solid":"20 ... 14","Width":"17.5 mm","at DC":"0.8 ... 1.1","title":"3RS7006-2FE00","Height":"93 mm","Upwards":"0 mm","Forwards":"0 mm","Stranded":"20 ... 14","Backwards":"0 mm","Downwards":"0 mm","Rise Time":"6 ms","At The Side":"0 mm","description":"Separation amplifier 24 V AC/DC, 3-way separation input: 0-60 mV, 0-100 mV 0-300 mV, 0-500 mV, 0-1 V 0-20 V, 2-10 V, 0-5 mA, 0-10 mA 2-10 V, 0-5 mA, 0-10 mA 0-20mA, 4-20 mA, +-5 mA, +-20 mA output: 0 - 10 V, 0/4 - 20 mA Spring-type terminal (push-in)","Input Voltage":"30 V","During Storage":"-40 ... +80 °C","at AC at 50 Hz":"0.8 ... 1.1","at AC at 60 Hz":"0.8 ... 1.1","Limit Frequency":"30 Hz","Type Of Voltage":"AC/DC","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"snap-on mounting","Product Category":"Signal converter","Mounting Position":"any","Between The Inputs":"No","Number Of Channels":"1","Product Brand Name":"SIRIUS","Between The Outputs":"No","Product Designation":"universal converter","at AWG cables solid":"1 x (20 ... 14)","display version LED":"Yes","protection class IP":"IP20","at 50 Hz rated value":"24 V","at 60 Hz rated value":"24 V","Consumed Active Power":"0.5 W","Design Of The Product":"active, switchable","Voltage Ripple Maximum":"20 mV","at AWG cables stranded":"1x (20 ... 14)","Type Of Signal At Input":"0 ... 60 mV, 0 ... 100 mV, 0 ... 300 mV, 0 ... 500 mV, 0 ... 1 V, 0 ... 2 V, 0 ... 5 V, 0 ... 10 V, 0 ... 20 V, 2 ... 10 V, 0 ... 5 mA, 0 ... 10 mA, 0 ... 20 mA, 4 ... 20 mA, +/-5 mA, +/-20 mA","Between Input And Output":"Yes","Type Of Signal At Output":"0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA","At Voltage Output Minimum":"2 kΩ","temperature drift per °C":"0.015 %/°C","Relative Metering Precision":"0.1 %","Relative Linearity Deviation":"0.05 %","At The Current Output Maximum":"500 Ω","Substance Prohibitance (Date)":"03/25/2015","Type Of Electrical Connection":"spring-loaded terminals","Settling Time For 1 % Deviation":"17 ms","supply voltage at DC rated value":"24 V","Design Of The Electrical Isolation":"3 paths","Relative Humidity During Operation":"10 ... 95 %","Supply Voltage Frequency Rated Value":"60 ... 50 Hz","Surge Voltage Resistance Rated Value":"4 000 V","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","due to burst according to IEC 61000-4-4":"1 kV 5/50 ns","reference code according to IEC 81346-2":"T","Finely Stranded With Core End Processing":"0.25 ... 1.5 mm²","Input Impedance Of Current Input Maximum":"100 Ω","Input Impedance Of Voltage Input Minimum":"330 kΩ","Property Of The Output Short-Circuit Proof":"Yes","Finely Stranded Without Core End Processing":"0.25 ... 2.5 mm²","shock resistance according to IEC 60068-2-27":"sinusoidal half-wave 15g / 11 ms","Between The Voltage Supply And Other Circuits":"Yes","vibration resistance according to IEC 60068-2-6":"6 ... 150 Hz: 2 g","EMC emitted interference according to IEC 60947-1":"Environment B","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","Installation Altitude At Height Above Sea Level Maximum":"2 000 m"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$554.91","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9c380a901f6bcc96948da8f8844eb9f4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=567466&mlfb=3RS7006-2FE00"},"ai":{"faq":[{"question":"What is the depth of the 3RS7006-2FE00?","answer":"The depth is 72.5 mm, which fits a standard 100 mm deep enclosure with wiring clearance behind it."},{"question":"What wire sizes does the 3RS7006-2FE00 accept?","answer":"It accepts 20 to 14 AWG solid or stranded wire, one conductor per terminal."},{"question":"Does the 3RS7006-2FE00 provide isolation between input and output?","answer":"Yes, there is galvanic isolation between input and output, which helps break ground loops in analog signal chains."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RS7006-2FE00","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RS7006-2FE00 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}