{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-1AF01-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-1AF01-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-1AF01-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-1AF01-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S00 power contactor, 3RT1015-1AF01-ZW97, 45 mm width, 7 A AC-3 at 400 V, 4 kW at 690 V, screw terminals, current production.","salesMarkdown":"It mounts via screw or snap-on onto a 35 mm DIN rail per EN 50022, with a 45 mm width that occupies three standard 17.5 mm modular pitches. The contactor is rated for AC-3 duty at 7 A at 400 V, delivering 3 kW at 400 V and 4 kW at 690 V — suitable for small induction motors on pumps, fans, and conveyors. The AC-4 rating of 6.5 A at 400 V is the one to watch if the contactor sees inrush from reversing or plugging — it's lower than the AC-3 figure, so a motor that starts fine may exceed the contactor's capability during a reversing cycle. Auxiliary contact ratings are given for DC switching: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V. These are the DC-13 values for inductive loads like relay coils; the 24 V rating is the one most often used for PLC-level control signals. This matters for selectivity studies in a panel — if upstream protection is set above 35 A, the contactor itself becomes the weakest link. This is the standard for most control panels without sealed enclosures. Electrical life will be shorter and depends on the switching current and duty cycle. ## Physical integration and wiring The depth includes the coil terminals and main contact terminals, so verify clearance to the enclosure door or gland plate. Screw terminals on the main circuit accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12. The terminal design allows two conductors per clamp, which simplifies daisy-chaining in a motor starter group. Front protection is IP20, meaning finger-safe from the front but not protected against water ingress. The terminal area is also IP20. This is standard for panel-mounted components — the enclosure provides the overall IP rating. ## Environmental limits Coil operating range is 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz — the wider 50 Hz tolerance accommodates brownout conditions common in industrial power systems.","metaTitle":"Siemens 3RT1015-1AF01-ZW97 SIRIUS S00 Power Contactor, 45mm","metaDescription":"Siemens SIRIUS 3RT1015-1AF01-ZW97 power contactor, size S00, 45mm wide, 7A AC-3 at 400V, 4kW at 690V. Current production. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"4 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=129018&mlfb=3RT1015-1AF01-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-1AF01-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for 3RT1015-1AF01-ZW97?","answer":"AC-3 motor switching: 7 A at 400 V, delivering 3 kW at 400 V and 4 kW at 690 V. AC-4 reversing/plugging: 6.5 A at 400 V. These are the ratings that determine motor fit."},{"question":"What fuse is required for short-circuit coordination?","answer":"Type 2 coordination (no damage): gL/gG 20 A fuse. Type 1 coordination (contactor may need replacement): gL/gG 35 A fuse."},{"question":"What is the physical size and mounting?","answer":"45 mm wide, 57.5 mm high, 72 mm deep. Screw or snap-on mounting onto 35 mm DIN rail per EN 50022. Side-by-side mounting is permitted without derating."},{"question":"What wire sizes does the screw terminal accept?","answer":"Main circuit terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded. AWG: 2x (20 to 16), 2x (18 to 14), 1x 12."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-1AF01-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-1AF01-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}