{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-1AG62","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-1AG62","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-1AG62","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-1AG62","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S00 power contactor, 3RT1015-1AG62, screw-type terminals, 10 A at 24 V rated value, AC-2/AC-4 duty, DIN-rail snap-on, IP20, 45 x 57.5 x 72 mm.","salesMarkdown":"It carries a 10 A rated value at 24 V, with AC-2 duty rated at 3 kW at 400 V and AC-4 duty at 6.5 A at 400 V — so it handles both starting and inching/plugging cycles on small induction motors up to that power class. Mounting is screw and snap-on onto 35 mm DIN rail per EN 50022, with a compact footprint of 45 mm width, 57.5 mm height, and 72 mm depth — fits standard panel spacing without crowding adjacent devices. Side clearance requirement is only 6 mm, which helps when packing multiple contactors on a rail. Front and terminal protection is IP20, so it's suitable for enclosed panels where accidental finger contact is the concern, not washdown environments. Main circuit terminals accept solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²). AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12. That covers standard motor and control wiring without needing special lugs. This matters when you're coordinating with motor protection breakers or fusible disconnects in the panel.","metaTitle":"Siemens 3RT1015-1AG62 SIRIUS S00 Power Contactor, 10 A at 24","metaDescription":"Siemens 3RT1015-1AG62 SIRIUS S00 power contactor, 10 A at 24 V, AC-2/AC-4 rated, screw terminals, DIN-rail mount, IP20. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"100 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"100 ... 110 V","at 690 V rated value":"4 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=301432&mlfb=3RT1015-1AG62","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-1AG62/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 3RT1015-1AG62 and how is it quoted for volume purchases?","answer":"The 3RT1015-1AG62 is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of 3RT1015-1AG62?","answer":"The contactor is rated 10 A at 24 V, with AC-2 duty at 3 kW at 400 V and AC-4 duty at 6.5 A at 400 V. It operates on 50/60 Hz at 100 to 110 V coil voltage."},{"question":"What is the mounting and clearance requirement for 3RT1015-1AG62?","answer":"It mounts via screw and snap-on onto 35 mm DIN rail per EN 50022, with a 45 x 57.5 x 72 mm footprint and only 6 mm side clearance needed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-1AG62","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-1AG62 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}