{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-1AP01-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-1AP01-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-1AP01-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-1AP01-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, 3RT1015-1AP01-ZW97, size S00, 3 kW at 400 V AC-2, 10 A AC-12, screw-type terminals, 45 mm width, IP20 front.","salesMarkdown":"Rated for AC-2 duty at 3 kW on a 400 V supply, this contactor handles slip-ring motor starting and reversing. The AC-4 rating of 6.5 A at 400 V covers plugging and inching duty cycles, while the AC-12 rating of 10 A covers resistive loads like heaters. The IP20 front protection means it's suited for enclosed panel use where tools or fingers won't contact live parts during operation. The ZW97 suffix indicates a special version — likely a customer-specific variant or a non-standard packaging. Confirm with your Siemens contact that the standard 3RT1015-1AP01 (without suffix) is a drop-in replacement if the ZW97 features aren't required for your application. Main circuit connections use screw-type terminals accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or a maximum of 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12. The depth of 72 mm leaves room for wiring ducts in the panel. For short-circuit coordination, a Type 2 assignment requires a gL/gG fuse rated 20 A, while Type 1 coordination allows up to 35 A. Side-by-side mounting is supported without derating, which simplifies multi-contactor groups. ## Environmental limits and endurance At 50 Hz the coil operates at 0.8 to 1.1 times rated voltage; at 60 Hz the range is 0.85 to 1.1. This gives a wider pickup tolerance at 50 Hz, useful if line voltage sags are common.","metaTitle":"Siemens SIRIUS 3RT1015-1AP01-ZW97 Power Contactor, Size S00,","metaDescription":"Siemens SIRIUS 3RT1015-1AP01-ZW97 power contactor, size S00, 3 kW at 400 V AC-2, 10 A AC-12. Screw terminals, 45 mm wide, IP20 front. Current production lifecycle. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"4 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=51724&mlfb=3RT1015-1AP01-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-1AP01-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What conductor sizes does the screw terminal accept?","answer":"The screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or a maximum of 2x (0.75 to 4 mm²) solid or stranded. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-1AP01-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-1AP01-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}