{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-1AP02-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-1AP02-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-1AP02-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-1AP02-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1015-1AP02-1AA0, 10 A AC-12 maximum operating current, screw-type terminals, snap-on DIN rail mounting.","salesMarkdown":"## SIRIUS S00 power contactor, 10 A AC-12, screw terminals The Siemens 3RT1015-1AP02-1AA0 is a SIRIUS-branded power contactor in the compact S00 frame size, rated for a maximum operating current of 10 A in AC-12 duty (resistive loads) and capable of switching motor loads up to 4 kW at 690 V in AC-3. The AC-12 rating of 10 A is the headline figure for resistive load switching — think heater banks or lighting contactor service. For motor duty, the AC-3 rating at 690 V (4 kW) is the one that governs the real-world fit; the AC-4 rating at 400 V (6.5 A) covers reversing or inching applications where the contactor makes and breaks stalled-rotor current. For a BOM freeze or long-term planning, this part is specified into the design without an imminent replacement risk. If you are maintaining a panel that was originally built around the larger-frame 3RT1016-1AG61, note that the S00 frame shares the same DIN-rail footprint and terminal pitch — the swap is mechanical, not electrical; the 3RT1015 carries lower current ratings, so verify the load before substituting. Main circuit terminals accept solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and a maximum of 2x (0.75 to 4 mm²). AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12. The screw-type termination is field-serviceable with a standard Pozidriv or flat-blade driver — no special crimp tool needed. ## Coil and auxiliary contact configuration The coil is rated for 230 V at 50 Hz and 230 V at 60 Hz, with an operating range of 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz. That means at 50 Hz the coil holds in down to 184 V and picks up reliably at 253 V; at 60 Hz the dropout margin is slightly tighter. No built-in auxiliary contacts are present — the instantaneous contact count is zero, so any feedback or status signaling requires an add-on auxiliary contact block. Auxiliary contact current ratings by voltage: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, and 3 A at 400 V. These are the switching capacities for the auxiliary contacts if an add-on block is fitted — useful when selecting a block for a 24 VDC PLC input or a 230 VAC pilot light. ## Short-circuit coordination and environmental limits For Type 2 coordination (contactor remains operational after a fault), the fuse is gL/gG 20 A.","metaTitle":"Siemens 3RT1015-1AP02-1AA0 SIRIUS S00 Power Contactor, 10 A","metaDescription":"Siemens 3RT1015-1AP02-1AA0 SIRIUS power contactor, size S00, 10 A AC-12 max, 4 kW at 690 V, screw terminals, snap-on DIN rail. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"4 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=297209&mlfb=3RT1015-1AP02-1AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-1AP02-1AA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1015-1AP02-1AA0?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"What is the difference between 3RT1015-1AP02-1AA0 and 3RT1016-1AG61?","answer":"The 3RT1016-1AG61 is a larger-frame contactor with higher current ratings. The 3RT1015-1AP02-1AA0 (S00 frame) shares the same DIN-rail footprint and terminal pitch, so it will physically drop into a panel wired for the 3RT1016. However, the 3RT1015 has lower AC-3 and AC-4 ratings — verify the load current before substituting. The 3RT1015 is not a direct electrical replacement; it is a mechanical fit only."},{"question":"What compliance documentation is available for 3RT1015-1AP02-1AA0?","answer":"As a current-production Siemens SIRIUS component, the 3RT1015-1AP02-1AA0 is manufactured under standard industrial compliance frameworks including RoHS, REACH, and relevant IEC/EN product standards. Specific declarations and certificates are available from Siemens upon request or through the product documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-1AP02-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-1AP02-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}