{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-2AB01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-2AB01","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-2AB01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AB01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 24 V 50/60 Hz coil, spring-loaded terminals, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"It's rated for a 24 V 50/60 Hz coil, pulling in at 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz. The main contacts are spring-loaded terminals, accepting 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). The contactor's switching capacity is defined by duty class. At AC-2 (slip-ring motor starting) at 400 V, it's rated for 3 kW. At AC-4 (plugging/inching) at 400 V, it handles 6.5 A. For resistive loads at 24 V, it's rated 10 A; at 230 V, 6 A; at 400 V, 3 A. Short-circuit coordination is specified: type 2 coordination requires a gL/gG fuse rated 20 A; type 1 coordination requires 35 A. This means the contactor can clear a fault without damage to the contactor itself (type 2) or with acceptable damage (type 1), depending on the upstream protection you select. Width is 45 mm, height 60 mm, depth 73 mm — a compact footprint that fits a standard DIN-rail enclosure. The contactor carries a substance prohibition date of 01.07.2006, indicating RoHS compliance from that date. The IEC 81346-2 reference code is Q, which designates it as a switching device in a power circuit. No UL or CSA listing is explicitly stated in the evidence, but the SIRIUS line typically carries these for the North American market — verify the specific nameplate marking if UL listing is required for your jurisdiction.","metaTitle":"Siemens 3RT1015-2AB01 SIRIUS Power Contactor, Size S00, 24V","metaDescription":"Siemens SIRIUS 3RT1015-2AB01 power contactor, size S00, 24V 50/60Hz coil, 10A rated at 24V. Spring-loaded terminals, DIN rail mount. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","at AWG cables for main contacts":"2x (24 ... 14)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"4.4 V·A","apparent pick-up power of magnet coil at AC":"27 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.8","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$72.01","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=295686&mlfb=3RT1015-2AB01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AB01/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the 3RT1015-2AB01?","answer":"The depth is 73 mm, with a width of 45 mm and height of 60 mm."},{"question":"What wire sizes does the 3RT1015-2AB01 accept?","answer":"The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG)."},{"question":"Will the 3RT1015-2AB01 drop into a panel specified around the 3RT1017-1AP01 without rewiring?","answer":"Not without checking the terminal type. The 3RT1015-2AB01 uses spring-loaded terminals; the 3RT1017-1AP01 uses screw-type terminals. The footprint (size S00, DIN rail mount) is the same, but the wiring method differs — you may need to re-terminate or use ferrules for the spring-loaded terminals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-2AB01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-2AB01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}