{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-2AF01-ZW98","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-2AF01-ZW98","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-2AF01-ZW98","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AF01-ZW98","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1015-2AF01-ZW98, size S00 power contactor, 7 A at 400 V AC-3, spring-loaded terminals, 45 mm width.","salesMarkdown":"Rated for AC-3 duty at 400 V, it handles motor loads up to 7 A, which translates to about 3 kW at 500 V and 4 kW at 690 V. For resistive loads (AC-1), the maximum operating current is 10 A. The contactor also carries AC-2 and AC-4 ratings: 3 kW at 400 V for AC-2 (slip-ring motor starting), and 6.5 A at 400 V for AC-4 (plugging/reversing duty). The 45 mm width, 60 mm height, and 73 mm depth make it a compact fit for dense DIN-rail layouts. The front face carries IP20 protection (finger-safe terminals), and the terminals themselves are also IP20. The spring-loaded terminals accept solid or stranded conductors from 0.25 to 2.5 mm² (2x per clamp), or AWG 24 to 14. Strip length is standard for spring-clamp terminations. For Type 1 coordination (contactor may need replacement after a fault), the fuse rating goes up to 35 A. This matters when you're sizing the upstream protection for a motor branch circuit — use the Type 2 value if you want to avoid replacing the contactor after a fault. Electrical life depends on the switching duty (AC-3 vs AC-4) and the actual current switched, but the mechanical figure gives you a ceiling for how long the armature and springs will hold up.","metaTitle":"Siemens SIRIUS 3RT1015-2AF01-ZW98 Power Contactor, S00, 7 A","metaDescription":"Siemens SIRIUS 3RT1015-2AF01-ZW98 power contactor, size S00, 7 A at 400 V AC-3. Spring-loaded terminals, 45 mm wide. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"4 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=497011&mlfb=3RT1015-2AF01-ZW98","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AF01-ZW98/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It's rated for AC-3 duty at 7 A, 400 V, with motor power ratings of 3 kW at 500 V and 4 kW at 690 V. The AC-1 resistive load rating is 10 A. Mechanical endurance is 30 million operations typical."},{"question":"What type of terminals does it use?","answer":"Spring-loaded terminals for the main current circuit, accepting 2x (0.25 to 2.5 mm²) solid or stranded conductors, or 2x (24 to 14 AWG)."},{"question":"Can it be mounted side-by-side with other contactors?","answer":"Yes, side-by-side mounting is permitted, so you can gang multiple units on a DIN rail without additional spacing."},{"question":"What fuse coordination is recommended?","answer":"For Type 2 coordination (no damage after short circuit), use a gL/gG fuse rated 20 A. For Type 1 coordination (contactor may need replacement), use a 35 A gL/gG fuse."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-2AF01-ZW98","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-2AF01-ZW98 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}