{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-2AF02-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-2AF02-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-2AF02-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AF02-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S00 power contactor, 3RT1015-2AF02-ZX95, 24 VDC coil, 10 A rated, spring-loaded terminals, screw and snap-on mounting to 35 mm DIN rail (EN 50022), 45 mm wide, 73 mm deep.","salesMarkdown":"That 10 A figure is the maximum continuous current for the main contacts in AC-12 duty (resistive loads at 24 V). For motor switching, the relevant rating is 3.5 kW at 500 V and 4 kW at 690 V — those are the values that govern whether this contactor handles a given pump, conveyor, or compressor motor. The S00 frame keeps the width to 45 mm, so it fits a standard DIN-rail panel without crowding adjacent devices. ## Termination and wiring — spring-loaded main contacts Main current circuit uses spring-loaded terminals, accepting 2x (0.25... 2.5 mm²) solid or stranded conductors (2x AWG 24... 14). The spring-cage design speeds panel wiring — no torque driver needed, just strip to 8–10 mm and push in. The control circuit terminals are also IP20 finger-safe, same as the front face. Type 1 coordination allows a 35 A gL/gG fuse. This matters when the panel is designed to a specific SCCR — the fuse choice directly affects the branch-circuit rating. ## Environmental and mounting limits Pollution degree 3 (conductive pollution, typical for industrial control panels). The contactor is rated for 30 million mechanical operations typical — a figure that governs maintenance intervals in high-cycle applications like shuttle cranes or pick-and-place cells.","metaTitle":"Siemens 3RT1015-2AF02-ZX95 SIRIUS S00 Power Contactor, 24 VD","metaDescription":"Siemens SIRIUS 3RT1015-2AF02-ZX95 S00 power contactor, 24 VDC coil rated 10 A. Spring-loaded terminals, DIN rail mount, current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"4 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=518395&mlfb=3RT1015-2AF02-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AF02-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1015-2AF02-ZX95?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional alternative to 3RT1015-2AF02-ZX95?","answer":"The 3RT1016-1AG61 is a larger-frame SIRIUS contactor with a different coil voltage and higher current rating — it will not drop into the same panel footprint without rewiring. The 3RT1015-2AF02-ZX95 is the S00-frame 24 VDC variant; if you need a different coil voltage, the 3RT1015-1AG61 (same frame, AC coil) is the direct peer within the same size class."},{"question":"What does the 73 mm depth mean for panel fit?","answer":"The 73 mm depth is the dimension from the DIN-rail mounting surface to the front of the contactor. It fits inside a standard 100 mm deep enclosure with clearance for wiring and heat dissipation."},{"question":"What compliance documentation does Siemens provide for this contactor?","answer":"Siemens SIRIUS contactors carry CE marking for the European market and are designed to IEC 60947-4-1. The manufacturer provides a declaration of conformity and RoHS/REACH compliance documentation upon request through the supply chain."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-2AF02-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-2AF02-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}