{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-2AG14","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-2AG14","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-2AG14","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AG14","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, size S00, 3RT1015-2AG14, 24 VDC coil, 10 A rated, spring-loaded terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"The Siemens 3RT1015-2AG14 is a SIRIUS power contactor in the compact Size S00 frame (45 mm wide, 60 mm tall, 114 mm deep) — the smallest footprint in the SIRIUS family, sized for panel density where every millimeter of DIN rail counts. It switches motor loads up to 3 kW in AC-2 duty at 400 V and handles 6.5 A in AC-4 reversing or plugging service, so it's suited for conveyor drives, pump starters, and small compressor controls inside a standard 35 mm DIN-rail enclosure per DIN EN 50022. The 24 VDC coil pulls in reliably at 10 A rated current (AC-12 maximum), and the contactor holds its seal across the full operating range of -25 to +60 °C. Spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded copper — no ferrule needed, no screw torque to verify. Side-by-side mounting is permitted (zero gap between contactors), which keeps the rail density high. For Type 2 coordination (no-weld requirement) the upstream fuse must be gL/gG 20 A; for Type 1 coordination (allow contactor damage) a 35 A gL/gG fuse is the limit.","metaTitle":"Siemens 3RT1015-2AG14 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens 3RT1015-2AG14 SIRIUS power contactor, size S00, 24 VDC coil, 10 A rated, spring-loaded terminals. AC-2 3 kW at 400 V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 60 Hz":"0.8 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"60 Hz","2 Rated Value":"50 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"100 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"4 kW","Instantaneous Contact":"2","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=152257&mlfb=3RT1015-2AG14","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AG14/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1015-2AG14 and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Submit a request for quote (RFQ) with your quantity; availability and current pricing are confirmed at quote time."},{"question":"What is 3RT1015-2AG14's listed depth?","answer":"The depth is 114 mm, which is the dimension from the DIN-rail mounting surface to the furthest forward point of the contactor body."},{"question":"What wire sizes does the spring-loaded terminal accept?","answer":"The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded copper conductors, or 2x (24 to 14 AWG)."},{"question":"Will 3RT1015-2AG14 drop into a panel specified for 3RT1016-2AP02?","answer":"Both are Size S00 contactors on the same 45 mm wide footprint with the same DIN-rail mounting pattern, so the mechanical fit is identical. The difference is in the coil voltage and load ratings — verify the 24 VDC coil and 10 A thermal rating match your circuit before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-2AG14","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-2AG14 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}