{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-2AP01-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-2AP01-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-2AP01-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AP01-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S00, 3RT1015-2AP01-ZX95, 24 VDC coil, spring-loaded terminals, IP20 front, screw and snap-on 35 mm DIN rail mounting.","salesMarkdown":"## Siemens 3RT1015-2AP01-ZX95 SIRIUS Power Contactor – Size S00, 24 VDC Coil The coil is rated for 24 VDC, and the contactor carries DC-1 switching ratings of 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — so for a 24 VDC control circuit it handles the full rated current, but derates significantly as voltage climbs. For AC motor duty, it is rated 3 kW at 400 V in AC-2 (slip-ring motor starting) and 6.5 A at 400 V in AC-4 (plugging/reversing), which tells you this is sized for small motor loads up to about 4 kW at 690 V. ## Termination and Wiring Main current circuit connections use spring-loaded terminals, accepting 2x (0.25... 2.5 mm²) solid or stranded wire, or 2x (24... 14) AWG. That's a standard terminal range for Size S00 — no special crimp tool needed for the spring cage, but make sure the strip length is clean to avoid whiskers under the clamp. The front face carries IP20 protection; the terminal area is also rated IP20, so it's touch-safe in a closed panel but not suitable for washdown environments. For Type 2 coordination (contactor remains operational after a fault), the fuse must be gL/gG 20 A.","metaTitle":"Siemens 3RT1015-2AP01-ZX95 SIRIUS Power Contactor, Size S00,","metaDescription":"Siemens 3RT1015-2AP01-ZX95 SIRIUS power contactor, Size S00, 24 VDC coil, 10 A DC-1, spring-loaded terminals, IP20, DIN rail mount. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"4 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=439513&mlfb=3RT1015-2AP01-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AP01-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source for 3RT1015-2AP01-ZX95?","answer":"The closest functional peer is the 3RT1016-1AG61, which shares the S00 frame and 24 VDC coil but uses screw terminals instead of spring-loaded connections. The 3RT1016-2AP02 also matches the spring-loaded terminal type but may differ in auxiliary contact configuration. Verify the auxiliary contact block count before substituting."},{"question":"What are the DC switching ratings for 3RT1015-2AP01-ZX95?","answer":"At 24 V it switches 10 A DC-1, at 60 V it switches 2 A, at 110 V it switches 1 A, and at 220 V it switches 0.3 A. These are resistive load (DC-1) ratings; inductive loads require derating."},{"question":"What compliance documentation does Siemens provide for 3RT1015-2AP01-ZX95?","answer":"As a standard SIRIUS product, Siemens typically provides a declaration of conformity (CE, UKCA), RoHS and REACH compliance statements, and UL/CSA recognition on the nameplate. Specific certificates should be requested at quote time for your jurisdiction."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-2AP01-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-2AP01-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}