{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-2AP02-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-2AP02-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-2AP02-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AP02-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS S00 power contactor, 3RT1015-2AP02-ZW97, spring-loaded terminals, 10 A DC-1 at 24 V, screw and snap-on 35 mm DIN rail, IP20.","salesMarkdown":"## SIRIUS S00 power contactor with spring terminals The Siemens 3RT1015-2AP02-ZW97 is a SIRIUS S00 power contactor sized for control-panel duty, with spring-loaded terminals on the main current circuit that accept 2x (0.25 to 2.5 mm²) solid or stranded copper — no screwdriver needed for wiring, which speeds panel build and eliminates torque-check on terminations. Mounts via screw or snap-on onto 35 mm standard DIN rail per DIN EN 50022, occupying a 45 mm wide footprint with 73 mm depth and 60 mm height — fits standard enclosure backplanes without oversizing the cabinet. Rated for continuous operation from -25 °C to +60 °C, with a maximum operating altitude of 2 000 m, and pollution degree 3 environment — suitable for unheated industrial halls and panel interiors near switching loads. ## DC switching capability across the voltage range For DC-1 resistive loads the contactor delivers 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — the current drops sharply as voltage rises because DC arc extinction is harder at higher potentials. At 230 V DC the rating is 6 A, and at 400 V DC it is 3 A. For AC motor duty, the contactor is rated 3 kW at AC-2 at 400 V (for slip-ring motor starting) and 6.5 A at AC-4 at 400 V (for reversing or inching duty where the contactor makes and breaks stalled-rotor current). The AC-12 maximum operating current is 10 A, which covers control-circuit switching of transformer or resistive loads in the same panel. ## Coordination and protection requirements This matters when the contactor sits in a motor branch circuit that must coordinate with the motor starter overload relay. The front and terminal faces carry IP20 finger-safe protection, so the contactor can be installed in a panel with the door open for commissioning without shock hazard from the terminals.","metaTitle":"Siemens 3RT1015-2AP02-ZW97 SIRIUS S00 Contactor, 10A DC-1","metaDescription":"Siemens 3RT1015-2AP02-ZW97 SIRIUS S00 power contactor, 10A DC-1 at 24V, spring terminals, IP20, current lifecycle. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"4 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"18 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=82861&mlfb=3RT1015-2AP02-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2AP02-ZW97/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1015-2AP02-ZW97 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional second-source to 3RT1015-2AP02-ZW97?","answer":"The 3RT1016-2AP02 is the next size up in the same SIRIUS S00 frame — it shares the same 45 mm width, DIN-rail footprint, and spring-terminal wiring, but carries higher AC-3 and DC ratings. It drops into the same panel cutout without rewiring, making it a direct swap if the load current exceeds the 3RT1015's rating."},{"question":"Will 3RT1015-2AP02-ZW97 drop into a panel specified around 3RT1016-2AP02 without rewiring?","answer":"Yes — both are S00 frame size with identical 45 mm width, 73 mm depth, and 35 mm DIN-rail snap-on mounting. The spring-terminal layout is the same, so no panel rework or re-termination is needed."},{"question":"What compliance documentation does Siemens provide for 3RT1015-2AP02-ZW97?","answer":"As a current-production SIRIUS component, it carries CE marking for the European low-voltage directive and is manufactured under Siemens' ISO 9001 quality system. Specific RoHS and REACH declarations are available from Siemens Industry Online Support."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-2AP02-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-2AP02-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}