{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-2GG22","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-2GG22","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-2GG22","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2GG22","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1015-2GG22, 24 VDC coil, 10 A rated operational current, spring-loaded terminals, screw and snap-on mounting onto 35 mm DIN rail.","salesMarkdown":"The Siemens SIRIUS 3RT1015-2GG22 is a size S00 power contactor rated for 10 A at 24 V, with a 24 VDC coil that includes a full-wave rectified surge suppressor built in. The AC-2 motor switching rating at 400 V is 3 kW, and the AC-4 rating at 400 V is 6.5 A — so it handles both standard motor starts and reversing or plugging duty cycles. Main and auxiliary/control circuits both terminate through spring-loaded terminals, which speeds panel wiring and eliminates periodic re-torquing. The 45 mm width and 60 mm height keep panel density reasonable. Side-by-side mounting is permitted, so no mandatory spacing gaps between contactors on the rail.","metaTitle":"Siemens SIRIUS 3RT1015-2GG22 Power Contactor, S00, 24 VDC, 1","metaDescription":"Siemens SIRIUS 3RT1015-2GG22 power contactor, size S00, 24 VDC coil, 10 A rated operational current. Spring-loaded terminals, DIN rail mount. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"3.5 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"4 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","Design Of The Surge Suppressor":"with full-wave rectification","at AWG cables for main contacts":"2x (24 ... 14)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"3.8 V·A","apparent pick-up power of magnet coil at AC":"3.8 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.9","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.9","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=266081&mlfb=3RT1015-2GG22","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2GG22/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Rated operational current is 10 A at 24 V. AC-2 motor switching at 400 V is rated for 3 kW; AC-4 at 400 V is rated for 6.5 A. The coil is 24 VDC with a built-in full-wave rectified surge suppressor."},{"question":"What is the physical size and mounting?","answer":"Size S00 frame: 45 mm wide, 60 mm high, 114 mm deep. Mounts via screw-and-snap-on onto 35 mm DIN rail per EN 50022. Side-by-side mounting is allowed without spacing."},{"question":"What wire sizes and termination type does it use?","answer":"Spring-loaded terminals on both main and auxiliary/control circuits. Accepts 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG)."},{"question":"What fuse coordination is required?","answer":"For type 2 coordination (no damage to the contactor), use a gL/gG 20 A fuse upstream. For type 1 coordination (contactor may need replacement after a fault), a gL/gG 35 A fuse is permitted."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-2GG22","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-2GG22 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}