{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1015-2HB41-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1015-2HB41-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1015-2HB41-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2HB41-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, 3RT1015-2HB41-ZX95, Size S00, 24 V DC coil, spring-loaded terminals for main circuit, AC-2 rated 3 kW at 400 V.","salesMarkdown":"It carries a 24 V DC coil with a holding power of 2.3 W, and its main circuit connects via spring-loaded terminals — no screwdriver needed for the power wires, which speeds up panel wiring and reduces loose-connection callbacks. For AC-4 inching and plugging duty it manages 6.5 A at 400 V. The AC-12 resistive load maximum is 10 A. The IP20 front and terminal protection means it is finger-safe inside an enclosure but not rated for washdown. Spring-loaded terminals on the main circuit accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). The auxiliary contact block is a separate add-on — the base unit carries one instantaneous contact. For Type 2 coordination (no-weld after fault), use a gL/gG fuse rated 20 A. For Type 1 coordination (welding allowed but no fire risk), the fuse can go up to 35 A. The contactor is rated for use at altitudes up to 2 000 m and ambient temperatures from -25 °C to +60 °C during operation, with pollution degree 3.","metaTitle":"Siemens 3RT1015-2HB41-ZX95 SIRIUS Power Contactor, S00, 24 V","metaDescription":"Siemens SIRIUS 3RT1015-2HB41-ZX95 power contactor, size S00, 24 VDC coil, spring-loaded terminals, AC-2 3 kW at 400 V. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","At The Side":"6 mm","Rated Value":"24 V","On The Front":"IP20","Initial Value":"0.7","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Full-scale value":"1.25","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"3.5 kW","at 690 V rated value":"4 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"3 kW","at AC-4 at 400 V rated value":"6.5 A","Closing power of magnet coil at DC":"2.3 W","Holding power of magnet coil at DC":"2.3 W","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"18 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"DC","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=55264&mlfb=3RT1015-2HB41-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1015-2HB41-ZX95/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1015-2HB41-ZX95?","answer":"Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and stock position are confirmed at quote time."},{"question":"What is the closest functional second-source to 3RT1015-2HB41-ZX95?","answer":"The closest sibling is the 3RT1015-1BB42, which shares the same S00 frame and 24 V DC coil but uses screw terminals instead of spring-loaded terminals on the main circuit. If your panel is wired with ferrules and screw clamps, the 1BB42 drops in without rewiring the control side — just check the main circuit termination preference."},{"question":"Will 3RT1015-2HB41-ZX95 drop into a panel specified around 3RT1015-1BB42 without rewiring?","answer":"Yes, the physical footprint (45 x 60 x 73 mm) and DIN-rail mounting are identical. The coil voltage is the same 24 V DC. The only difference is the main circuit termination: spring-loaded on this unit versus screw clamps on the 1BB42. If your existing wiring uses screw terminals, you will need to adapt or re-terminate the power wires for the spring cage."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1015-2HB41-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1015-2HB41-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}