{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AB01-1AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AB01-1AA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AB01-1AA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB01-1AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1016-1AB01-1AA0, 24 V AC/DC coil, screw terminals, snap-on 35 mm DIN rail.","salesMarkdown":"It's a current-production part. Coil is 24 V rated, accepting both AC and DC (50 Hz and 60 Hz), with a rated operating range of 0.8...1.1 at 50 Hz and 0.85...1.1 at 60 Hz. That means the coil holds in reliably even if the control voltage sags a bit — good for long cable runs from a PLC output. Main contacts are screw-type terminals, accepting 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), and max 2x (0.75...4 mm²) solid or stranded. AWG equivalents: 2x (20...16), 2x (18...14), 1x 12. That's enough wire range for most motor circuits up to 5.5 kW. AC-4 at 400 V gives 8.5 A, covering plugging and inching applications. For resistive loads (AC-12), it handles 10 A continuous. At 690 V it's rated 5.5 kW, which is the typical max for this frame size. That's enough for a 7.5 HP motor at 480 V or a 5.5 kW motor at 690 V, but check your actual load current — the motor FLA is what matters, not the kW rating alone. Short-circuit coordination: Type 2 requires a 20 A gL/gG fuse; Type 1 allows a 35 A gL/gG. Type 2 means the contactor remains usable after a fault — the fuse clears before the contacts weld. If your panel spec calls for Type 2, you need the 20 A fuse. Mechanical life is typical 30 million operations — that's the mechanical endurance, not electrical. Electrical life will be lower depending on load current and duty cycle, but 30 million means the actuator and spring system are built for years of cycling in a machine. That's tight — you can pack multiple contactors in a row without extra spacing, but keep the 6 mm for heat dissipation. IP20 on the front and at the terminals — finger-safe, but not washdown. That's the standard S00 footprint — fits in the same space as any other S00 contactor from the SIRIUS family. ## Auxiliary and control circuit One instantaneous auxiliary contact (1 NO or 1 NC — the order code suffix determines which). For 24 V DC control, the contact is rated 10 A at 24 V, derating to 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, and 6 A at 230 V AC. That's enough to signal a PLC input or drive a small indicator lamp. The coil draws its rated voltage at 24 V. The wide operating range (0.8...1.1 at 50 Hz) means it picks up reliably even if the supply dips.","metaTitle":"Siemens 3RT1016-1AB01-1AA0 SIRIUS Power Contactor, S00, 24 V","metaDescription":"Siemens 3RT1016-1AB01-1AA0 SIRIUS power contactor. Size S00, 24 VAC/DC coil, 4 kW at AC-2 400 V, 5.5 kW at 690 V. Screw terminals, snap-on DIN rail. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=347488&mlfb=3RT1016-1AB01-1AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB01-1AA0/alternatives.json"},"ai":{"faq":[{"question":"What wire sizes does the screw terminal accept?","answer":"Screw terminals accept 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), and max 2x (0.75...4 mm²) solid or stranded; AWG equivalents are 2x (20...16), 2x (18...14), 1x 12."},{"question":"Will 3RT1016-1AB01-1AA0 drop into a panel specified around 3RT1016-1AR11 without rewiring?","answer":"Both are S00 frame size on 35 mm DIN rail, so the footprint and mounting are the same. The main difference is the coil voltage and auxiliary configuration — verify the coil matches your control voltage and the auxiliary contact count before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AB01-1AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AB01-1AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}