{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AB01-ZW95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AB01-ZW95","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AB01-ZW95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB01-ZW95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1016-1AB01-ZW95 power contactor, size S00, 24 V 50/60 Hz coil, screw-type terminals, IP20 front, 45 mm width.","salesMarkdown":"## SIRIUS S00 Power Contactor, 24 V Coil It carries a 24 V 50/60 Hz coil, draws its control voltage from a standard 24 V supply, and terminates main circuit wiring through screw-type terminals. Rated operational current at 400 V is 3 A, and at 690 V it delivers 5.5 kW, making it suited for smaller three-phase motors, contactor banks, or auxiliary switching duties where the S00 footprint fits. The AC-2 rating at 400 V is 4 kW, covering wound-rotor motor starting; the AC-4 rating at 400 V is 8.5 A, which governs plugging and inching duty cycles. For resistive loads, the AC-12 maximum operating current is 10 A. Main circuit terminals accept solid conductors from 2x (0.5 to 1.5 mm²) up to 2x (0.75 to 4 mm²), or stranded equivalents, with AWG sizes from 2x (20 to 16) up to 1x 12. Auxiliary contact configuration is 1 NO instantaneous contact, which can be used for feedback to a PLC or to seal in the coil circuit. ## Short-Circuit Coordination This guides the upstream protection selection when the contactor is part of a motor branch circuit. For BOM freeze or AML adherence, the 3RT1016-1AB01-ZW95 is a standard catalog item from Siemens SIRIUS family — no deviation needed if it is on the customer's approved vendor list.","metaTitle":"Siemens 3RT1016-1AB01-ZW95 SIRIUS Power Contactor, S00, 24V","metaDescription":"Siemens SIRIUS 3RT1016-1AB01-ZW95 power contactor, size S00, 24V 50/60Hz coil, screw terminals, IP20 front, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=395716&mlfb=3RT1016-1AB01-ZW95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB01-ZW95/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It has a 24 V 50/60 Hz coil, rated operational current of 3 A at 400 V, and delivers 5.5 kW at 690 V. AC-4 rating is 8.5 A at 400 V, and AC-12 maximum is 10 A. Mechanical life is 30,000,000 cycles typical."},{"question":"What wire sizes does the screw terminal accept?","answer":"Solid conductors from 2x (0.5 to 1.5 mm²) up to 2x (0.75 to 4 mm²), with stranded equivalents. AWG sizes range from 2x (20 to 16) up to 1x 12."},{"question":"What is the mounting method and panel footprint?","answer":"It mounts via screw or snap-on onto a 35 mm DIN rail per EN 50022, with dimensions of 45 mm width, 57.5 mm height, and 72 mm depth. Side-by-side mounting is permitted."},{"question":"What short-circuit protection is required?","answer":"For Type 1 coordination, use a 35 A gL/gG fuse; for Type 2 coordination (no damage to the contactor), use a 20 A gL/gG fuse."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AB01-ZW95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AB01-ZW95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}