{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AB01-ZW98","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AB01-ZW98","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AB01-ZW98","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB01-ZW98","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1016-1AB01-ZW98 power contactor, Size S00, 45 mm width, 10 A at 24 V, screw terminals, snap-on DIN rail mount.","salesMarkdown":"The Siemens 3RT1016-1AB01-ZW98 is a SIRIUS power contactor in the compact Size S00 frame — 45 mm wide, 57.5 mm tall, 72 mm deep — designed for switching motor loads and resistive circuits in industrial control panels. Rated 10 A at 24 V (AC-12), it handles motor starts and stops in the AC-3 duty class — the 24 V 50/60 Hz coil draws from a standard control transformer, and the contactor is rated for 50 Hz and 60 Hz operation. The 10 A AC-12 rating means this contactor is sized for resistive loads up to that current at 24 V; for motor duty (AC-3) at 400 V it delivers 4 kW, and at 690 V it delivers 5.5 kW — the higher voltage yields more power through the same frame because motor current drops at higher line voltage. For inductive motor switching (AC-4) at 400 V, the contactor is rated 8.5 A — that's the breaking current under severe starting duty, lower than the AC-3 rating because the arc is harder to quench when switching stalled-rotor current. The auxiliary contact block carries a single instantaneous contact rated 10 A at 24 V, 6 A at 230 V, and 0.3 A at 220 V DC — the DC rating drops sharply with voltage due to the sustained arc in DC circuits. Type 2 coordination (no weld under short circuit) requires a 20 A gL/gG fuse upstream; Type 1 coordination (device may be damaged but no fire) allows a 35 A gL/gG fuse — this matters for selectivity studies in the panel. Main circuit terminals are screw-type, accepting solid conductors: 2x 0.5–1.5 mm², 2x 0.75–2.5 mm², and up to 2x 0.75–4 mm² stranded — or AWG equivalents 2x 20–16, 2x 18–14, and 1x 12. Operating temperature range is -25 to +60 °C, with a maximum altitude of 2 000 m without derating; pollution degree 3 means it tolerates conductive dust in typical industrial enclosures.","metaTitle":"Siemens 3RT1016-1AB01-ZW98 SIRIUS Power Contactor, Size S00,","metaDescription":"Siemens SIRIUS 3RT1016-1AB01-ZW98 power contactor, Size S00, 10 A rated at 24 V, screw terminals, snap-on DIN rail mount. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=361460&mlfb=3RT1016-1AB01-ZW98","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB01-ZW98/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Rated 10 A at 24 V (AC-12), 4 kW at 400 V AC-3 motor duty, 5.5 kW at 690 V AC-3. Coil is 24 V 50/60 Hz. Size S00 frame, 45 mm wide."},{"question":"What fuse coordination does this contactor require?","answer":"For Type 2 coordination (no weld), use a 20 A gL/gG fuse. For Type 1 coordination, a 35 A gL/gG fuse is allowed."},{"question":"What is the difference between this and the 3RT1016-2AP02?","answer":"The 3RT1016-2AP02 is a variant with different coil voltage or auxiliary contact configuration — the main contactor frame and current ratings are identical. Verify the coil voltage on your BOM before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AB01-ZW98","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AB01-ZW98 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}