{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AB02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AB02","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AB02","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1016-1AB02 power contactor, Size S00, 10 A at 24 V, 4.5 kW at 500 V, 5.5 kW at 690 V, screw-type terminals, IP20, snap-on DIN rail mount.","salesMarkdown":"Rated for 10 A at 24 V and motor power up to 4.5 kW at 500 V or 5.5 kW at 690 V, this contactor handles typical three-phase induction motors in pump, fan, and conveyor applications. The screw-type terminals on both main and auxiliary circuits accept 2x (0.5 to 1.5 mm²) solid or stranded, up to 2x 4 mm², with AWG equivalents 2x (20 to 16) and 1x 12. For motor loads, the 4.5 kW at 500 V and 5.5 kW at 690 V figures tell you the maximum three-phase induction motor this contactor can switch under AC-3 duty (starting and running). If your motor is smaller, you're fine — these are maximums, not minimums. If your application does frequent reversing or jogging, use the AC-4 figure, not the AC-3 motor kW rating. Side-by-side mounting is permitted, which helps when packing multiple contactors into a tight panel. For type of coordination 2 (limited damage under short circuit), use a gL/gG fuse rated 20 A. For type 1 (no damage to the contactor, but may need replacement), use 35 A. This is critical for sizing upstream protection — don't guess. The coil is 24 V at 50/60 Hz, with a tolerance band of 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz. That means it picks up reliably even if your control supply sags to about 19 V at 50 Hz. RoHS compliance is confirmed with a substance prohibition date of 01.07.2006, covering the original EU RoHS directive.","metaTitle":"Siemens 3RT1016-1AB02 SIRIUS Power Contactor, 10 A at 24 V,","metaDescription":"Siemens SIRIUS 3RT1016-1AB02 power contactor, Size S00, 10 A at 24 V, 4.5 kW at 500 V, 5.5 kW at 690 V. Screw terminals, DIN rail mount. Current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"5.5 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","apparent holding power of magnet coil at AC":"4.4 V·A","apparent pick-up power of magnet coil at AC":"27 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.8","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$54.01","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=389129&mlfb=3RT1016-1AB02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB02/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AB02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AB02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}