{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AB02-ZW96","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AB02-ZW96","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AB02-ZW96","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB02-ZW96","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1016-1AB02-ZW96, 45 mm width, 4.5 kW at 500 V AC-3, screw terminals, 24 V 50/60 Hz coil.","salesMarkdown":"Rated for AC-3 duty at 4.5 kW on 500 V and 5.5 kW on 690 V, this contactor handles typical three-phase induction motor loads up to those power levels. The 45 mm width and 72 mm depth keep this S00 contactor slim for high-density panel layouts. Side-by-side mounting is permitted. Coil rated for 50 Hz and 60 Hz at 24 V. Operating range is 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz. Screw-type terminals on the main circuit accept solid conductors from 0.5 to 4 mm² (2x 0.75 to 4 mm² max), with AWG equivalents from 20 to 12. The auxiliary contact block handles 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — enough for pilot duty or PLC input signaling. Front and terminal protection is IP20, so it's touch-safe but not washdown-rated. For Type 1 coordination (contactor may need replacement after a fault), the fuse rating goes up to 35 A gL/gG. This matters when you're designing a motor branch circuit to a specific SCCR target.","metaTitle":"Siemens 3RT1016-1AB02-ZW96 SIRIUS Power Contactor, Size S00,","metaDescription":"Siemens SIRIUS 3RT1016-1AB02-ZW96 power contactor, size S00, 45 mm width, rated 4.5 kW at 500 V AC-3. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=11450&mlfb=3RT1016-1AB02-ZW96","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AB02-ZW96/alternatives.json"},"ai":{"faq":[{"question":"What is the physical size of the 3RT1016-1AB02-ZW96?","answer":"It measures 45 mm wide, 57.5 mm high, and 72 mm deep — the S00 frame size for compact panel mounting on 35 mm DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AB02-ZW96","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AB02-ZW96 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}