{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AC01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AC01","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AC01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AC01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1016-1AC01 power contactor, S00 frame, 4.5 kW at 500 V / 5.5 kW at 690 V, 24 V coil, screw terminals, IP20 front, 45 mm wide.","salesMarkdown":"Rated for 4.5 kW at 500 V and 5.5 kW at 690 V, this contactor handles common three-phase motor duties. The 24 V coil draws 10 A at rated value, which is typical for PLC-driven control circuits. The S00 frame keeps the footprint compact at 45 mm wide, 57.5 mm high, and 72 mm deep — sized for dense panel layouts where every rail millimeter counts. For AC-2 duty (slip-ring motors), it is rated 4 kW at 400 V. These duty-specific numbers, not the thermal current, govern real motor-switching life. Type 1 coordination requires a 35 A gL/gG fuse upstream; Type 2 coordination requires a 20 A gL/gG fuse. This determines the short-circuit protection scheme and whether the contactor remains usable after a fault. Main circuit terminals are screw-type, accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12. This covers typical motor leads and panel wiring without needing special ferrules. Front protection is IP20, so the contactor is touch-safe once installed in an enclosure. Because it is an active, standard SIRIUS S00 contactor, sourcing runs through normal Siemens distribution channels. We can quote this against an RFQ for BOM-line fills or scheduled production orders.","metaTitle":"Siemens 3RT1016-1AC01 SIRIUS Power Contactor, S00, 4.5 kW at","metaDescription":"Siemens SIRIUS 3RT1016-1AC01 power contactor, S00 frame, 4.5 kW at 500 V, 5.5 kW at 690 V, 24 V coil, screw terminals, current lifecycle stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"32 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"32 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=41014&mlfb=3RT1016-1AC01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AC01/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is rated 4.5 kW at 500 V and 5.5 kW at 690 V for AC-3 motor duty. The AC-4 rating at 400 V is 8.5 A. The coil is 24 V, drawing 10 A at rated value. Operating temperature is -25 to +60 °C."},{"question":"What wire sizes does the screw terminal accept?","answer":"The main circuit terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded, with AWG equivalents of 2x (20 to 16), 2x (18 to 14), or 1x 12."},{"question":"What short-circuit protection is required?","answer":"Type 1 coordination requires a 35 A gL/gG fuse; Type 2 coordination requires a 20 A gL/gG fuse upstream."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AC01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AC01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}