{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AK62","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AK62","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AK62","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AK62","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1016-1AK62 power contactor, size S00, 45 mm width, 10 A rated at 24 V, 5.5 kW at 690 V, screw terminals, DIN rail mount.","salesMarkdown":"The Siemens SIRIUS 3RT1016-1AK62 is a size S00 power contactor, rated for switching motor loads up to 5.5 kW at 690 V and 4.5 kW at 500 V. At 24 V it carries 10 A, and at 230 V it carries 6 A. For standard AC-3 motor starting, the rated power at 400 V is 4 kW. Wire termination uses screw-type terminals for both main and auxiliary circuits, accepting solid or stranded conductors from 0.5 to 4 mm² (AWG 20 to 12). The front and terminal areas carry IP20 protection — safe for finger contact inside a closed panel. ## Panel integration and coordination Side-by-side mounting is permitted, so multiple contactors can be ganged without spacing. For Type 2 coordination (no-weld protection), the required upstream fuse is 20 A gL/gG; for Type 1 coordination (allow weld), a 35 A gL/gG fuse is specified.","metaTitle":"Siemens SIRIUS 3RT1016-1AK62 Power Contactor, S00, 10 A at 2","metaDescription":"Siemens SIRIUS 3RT1016-1AK62 power contactor, size S00, 45 mm width, 10 A rated at 24 V, 5.5 kW at 690 V. Active lifecycle, screw terminals, DIN rail mount. Source to order via RFQ","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.8 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"120 V","at 690 V rated value":"5.5 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","apparent holding power of magnet coil at AC":"5.1 V·A","apparent pick-up power of magnet coil at AC":"31.7 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.77","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"1","number of NO contacts for auxiliary contacts instantaneous contact":"0","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=453044&mlfb=3RT1016-1AK62","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AK62/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is rated for 5.5 kW at 690 V, 4.5 kW at 500 V, 10 A at 24 V, and 6 A at 230 V. AC-4 switching current at 400 V is 8.5 A. Mechanical life is 30 million operations."},{"question":"What wire sizes does the screw terminal accept?","answer":"The main and auxiliary screw terminals accept solid or stranded conductors from 0.5 to 4 mm² (AWG 20 to 12), with a maximum of two conductors per clamp."},{"question":"What fuse coordination is required?","answer":"For Type 2 coordination (no weld), use a 20 A gL/gG fuse upstream. For Type 1 coordination (weld allowed), a 35 A gL/gG fuse is specified."},{"question":"Can this contactor be mounted side-by-side?","answer":"Yes, side-by-side mounting is permitted, so multiple contactors can be ganged without spacing on the DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AK62","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AK62 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}