{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AM15-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AM15-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AM15-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AM15-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1016-1AM15-ZX95, 24 VDC coil, 10 A rated operational current, 3-pole, screw terminals, 45 mm width.","salesMarkdown":"## What It Is — SIRIUS S00 Power Contactor The IP20 rating on the front and terminals means it's finger-safe for panel installation but not intended for washdown environments — keep it behind a cabinet door. Pollution degree 3 tolerance lets it handle conductive dust and humidity typical of factory floors without derating. ## Sourcing & Lifecycle — Current Production Current production. The ZX95 suffix indicates a special version — verify coil voltage and terminal configuration. Snap it onto the DIN rail first, then land the power wires. The 45 mm width means it occupies three 15 mm module positions on the rail — plan your gland plate and wireway fill accordingly. Add clearance for wire bending and screwdriver access.","metaTitle":"Siemens 3RT1016-1AM15-ZX95 SIRIUS Power Contactor, S00, 24 V","metaDescription":"Siemens SIRIUS 3RT1016-1AM15-ZX95 power contactor, size S00, 24 VDC coil, 10 A rated current. Current production. Sourced to order. 45 mm wide, screw terminals.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 60 Hz":"0.8 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"60 Hz","2 Rated Value":"50 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"189 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"208 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"3","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=499679&mlfb=3RT1016-1AM15-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AM15-ZX95/alternatives.json"},"ai":{"faq":[{"question":"Will this drop into a panel wired for a 3RT1016-2AP02?","answer":"The 3RT1016-1AM15-ZX95 shares the same S00 frame and DIN rail footprint as the 2AP02 variant, so the mechanical fit and terminal layout are identical. The difference is in the coil voltage and auxiliary contact configuration — verify those match your control circuit before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AM15-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AM15-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}