{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AP01-ZW98","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AP01-ZW98","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AP01-ZW98","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AP01-ZW98","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1016-1AP01-ZW98, 24 V coil rated 10 A, screw terminals, DIN rail snap-on mounting, 45 x 57.5 x 72 mm.","salesMarkdown":"## SIRIUS Size S00 power contactor, 24 V coil The coil holds at 24 V nominal; the 10 A rating at that voltage covers the pick-up inrush typical of contactor coils in this class. At 60 V the rated current drops to 2 A, at 110 V to 1 A, and at 220 V to 0.3 A — the coil draw falls as supply voltage rises, which is the expected curve for a DC-operated solenoid. ## DIN rail integration and terminal wiring The 45 mm wide, 57.5 mm tall, 72 mm deep footprint fits tightly against adjacent devices — side-by-side mounting is permitted with a 6 mm gap to the side for heat dissipation. Front face carries IP20 finger-safe protection; the terminals themselves are also IP20, so the contactor can sit in a non-sealed enclosure as long as the front is not exposed to tools. Main circuit terminals accept screw-type connections: 2x (0.5–1.5 mm²), 2x (0.75–2.5 mm²), or max 2x (0.75–4 mm²) solid/stranded. For AWG, that's 2x (20–16), 2x (18–14), or 1x 12. The dual-wire entry helps when looping through to a downstream overload relay without an extra terminal block. ## Switching capacity and coordination For motor loads in AC-2 duty at 400 V, the contactor is rated for 4 kW; in AC-4 (plugging/inching) at 400 V it handles 8.5 A. The AC-12 maximum operating current is 10 A, which matches the coil rating — useful for resistive or transformer-coupled loads. Rated operational voltage covers 50 Hz at 230 V and 60 Hz at 230 V. The contactor is also rated for switching at 500 V (4.5 kW) and 690 V (5.5 kW) — those are the motor power figures for the main poles, not the coil circuit. The coil itself sees only the 24 V control voltage.","metaTitle":"Siemens 3RT1016-1AP01-ZW98 SIRIUS Power Contactor, Size S00,","metaDescription":"Siemens SIRIUS 3RT1016-1AP01-ZW98 power contactor, size S00, 24 V coil rated 10 A. Current lifecycle stage. DIN rail mount. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=86433&mlfb=3RT1016-1AP01-ZW98","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AP01-ZW98/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AP01-ZW98","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AP01-ZW98 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}