{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AP02-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AP02-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AP02-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AP02-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1016-1AP02-ZW97 power contactor, size S00, 45 mm width, 72 mm depth, screw-type terminals, 4.5 kW at 500 V / 5.5 kW at 690 V motor rating.","salesMarkdown":"The front face carries IP20 protection; the terminals themselves are also rated IP20, so the part is suited for enclosed panel use where no washdown or dust ingress is expected. Rated for motor switching at 4.5 kW on a 500 V 50 Hz supply and 5.5 kW at 690 V, this contactor handles typical three-phase induction motors up to that power band — think small conveyors, pumps, or fan drives. The AC-2 rating at 400 V gives 4 kW, which is the duty for slip-ring motors; the AC-4 rating at 400 V is 8.5 A, covering reversing or inching applications where the contactor makes and breaks under load. For DC switching, the 24 V coil draws 10 A, dropping to 2 A at 60 V and 0.3 A at 220 V — useful for braking or DC injection circuits. Main circuit terminals are screw-type, accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded copper — the range covers most control panel wiring from signal-level to motor feeder. Type 1 coordination (contactor may need replacement after fault) allows a 35 A fuse. The 57.5 mm height keeps it below common enclosure gland-plate clearances.","metaTitle":"Siemens SIRIUS 3RT1016-1AP02-ZW97 Power Contactor, S00 Frame","metaDescription":"Siemens SIRIUS 3RT1016-1AP02-ZW97 power contactor, size S00, 45 mm width, 72 mm depth. 4.5 kW at 500 V, 5.5 kW at 690 V. Screw terminals. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=354697&mlfb=3RT1016-1AP02-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AP02-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to this contactor?","answer":"The 3RT1016-2AP02 is the same base frame size S00 with similar electrical ratings but uses spring-cage terminals instead of screw-type. If your panel wiring is already spec'd for screw terminals, the -1AP02 variant is the direct fit; the -2AP02 would require a terminal adapter or re-termination at the panel level."},{"question":"What are the key dimensions for panel layout?","answer":"Width is 45 mm, height is 57.5 mm, and depth is 72 mm. It mounts on a 35 mm DIN rail per EN 50022, and side-by-side mounting is allowed without additional spacing."},{"question":"What wire sizes does the screw terminal accept?","answer":"The main circuit terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) solid or stranded copper. For AWG, it accepts 2x (20 to 16), 2x (18 to 14), or 1x 12."},{"question":"What short-circuit protection is required?","answer":"For Type 2 coordination (no damage to the contactor), use a gL/gG fuse rated at 20 A. For Type 1 coordination (contactor may be damaged), a 35 A fuse is permitted."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AP02-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AP02-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}