{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-1AP05-ZW97","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-1AP05-ZW97","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-1AP05-ZW97","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AP05-ZW97","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1016-1AP05-ZW97, frame size S00, 24 VDC coil, 10 A rated operating current, screw-type terminals, snap-on 35 mm DIN rail.","salesMarkdown":"It carries a 24 VDC coil and is rated for 10 A operating current at AC-12 (resistive) duty, with motor-switching capability across AC-2 and AC-4 categories — 4 kW at AC-2 / 400 V, and 8.5 A at AC-4 / 400 V for reversing or plugging duty. Side-by-side mounting is permitted — no derating gap needed between units. The S00 footprint (45 mm wide, 57.5 mm tall, 114 mm deep) fits tight sub-panel layouts typical of smaller motor control centers. ## Wiring and terminal capacity Main circuit terminals are screw-type, accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents: 2x (20 to 16), 2x (18 to 14), or 1x 12. The IP20 finger-safe terminal covers protect against accidental contact during panel wiring. Coil operates at 24 VDC with a pickup range of 0.8 to 1.1 x rated voltage at 50 Hz (0.85 to 1.1 at 60 Hz). Type 2 coordination requires 20 A. This matters when specifying upstream protection for a motor branch circuit — Type 2 keeps the contactor reusable after a fault. ## Environmental limits The front face is rated IP20, so the contactor itself is not washdown-rated — it relies on the panel enclosure for environmental sealing.","metaTitle":"Siemens 3RT1016-1AP05-ZW97 SIRIUS Contactor, S00, 24 VDC, 10","metaDescription":"Siemens SIRIUS 3RT1016-1AP05-ZW97 power contactor, frame size S00, 24 VDC coil, 10 A rated. Screw/snap-on DIN rail. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"3","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=209529&mlfb=3RT1016-1AP05-ZW97","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-1AP05-ZW97/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT1016-1AP05-ZW97?","answer":"The depth is 114 mm, with a width of 45 mm and height of 57.5 mm, fitting the S00 frame size."},{"question":"What wire sizes does the main terminal accept?","answer":"Screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded; AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12."},{"question":"How do I get current pricing and availability for 3RT1016-1AP05-ZW97?","answer":"Pricing and availability are confirmed at quote time against an RFQ through independent distribution channels — submit a request for current figures."},{"question":"Will 3RT1016-1AP05-ZW97 drop into a panel specified around 3RT1016-1AR11?","answer":"Both are S00 frame size contactors with the same 45 mm width, 57.5 mm height, and 114 mm depth, so the physical footprint is identical. The key difference is the coil voltage — this unit is 24 VDC, while the 3RT1016-1AR11 uses a different coil rating. Verify coil compatibility before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-1AP05-ZW97","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-1AP05-ZW97 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}