{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-2AB01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-2AB01","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-2AB01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AB01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 24 VAC 50/60 Hz coil, spring-loaded terminals, 10 A at 24 V, IP20.","salesMarkdown":"The main contacts are rated for 10 A at 24 V, with motor-switching capability up to 4.5 kW at 500 V and 5.5 kW at 690 V. ## Mounting and termination Both the main current circuit and the auxiliary/control circuit use spring-loaded terminals, accepting 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). Strip length and ferrule sizing follow standard practice for this terminal class. The contactor measures 45 mm wide, 60 mm tall, and 73 mm deep — the depth figure matters when planning gland-plate clearance or enclosure depth for a multi-contactor cluster. ## Environmental and coordination The enclosure and terminals carry an IP20 rating — finger-safe but not washdown-rated; this is a panel-interior component, not a field-mounted device. This is the selectivity decision for the panel builder. The IEC 81346-2 reference code is Q, for switching devices.","metaTitle":"Siemens 3RT1016-2AB01 SIRIUS Power Contactor, S00, 24 VAC 50","metaDescription":"Siemens 3RT1016-2AB01 SIRIUS power contactor, size S00, 24 VAC 50/60 Hz coil, spring-loaded terminals, rated 10 A at 24 V, IP20. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"5.5 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","at AWG cables for main contacts":"2x (24 ... 14)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"4.4 V·A","apparent pick-up power of magnet coil at AC":"27 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.8","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=491702&mlfb=3RT1016-2AB01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AB01/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the 3RT1016-2AB01?","answer":"The coil is 24 VAC 50/60 Hz. Main contacts are rated 10 A at 24 V, with motor power ratings of 4.5 kW at 500 V and 5.5 kW at 690 V. For AC-4 duty, it is rated 8.5 A at 400 V. It mounts on 35 mm DIN rail and uses spring-loaded terminals for both main and auxiliary circuits."},{"question":"What compliance documentation is available for the 3RT1016-2AB01?","answer":"RoHS compliance is established with a substance prohibition date of July 1, 2006. The product is designed for pollution degree 3 per IEC standards. The IEC 81346-2 reference code is Q."},{"question":"What is the physical size of the 3RT1016-2AB01?","answer":"It measures 45 mm wide, 60 mm tall, and 73 mm deep. This is the S00 frame size."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-2AB01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-2AB01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}