{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-2AF01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-2AF01","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-2AF01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AF01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1016-2AF01, Size S00, 45 mm width, spring-loaded terminals, 10 A at 24 V rated operational current, 8.5 A AC-4 at 400 V.","salesMarkdown":"Rated operational current is 10 A at 24 V, with AC-4 switching capability of 8.5 A at 400 V — that's the reversing or inching duty cycle that wears contacts fastest, so this rating tells you the contactor can handle frequent jogging or plugging without premature failure. At 500 V it's rated for 4.5 kW motor power, and at 690 V for 5.5 kW, covering standard European low-voltage motor circuits. Main and auxiliary circuits use spring-loaded terminals, accepting 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). That's a tool-less connection — strip, push, done — which shaves minutes per termination on a multi-contactor panel. The 45 mm wide footprint and 73 mm depth fit the Size S00 envelope, and side-by-side mounting is permitted with no derating gap — that's another SKU I don't need for spacing brackets. For type 1 coordination (contactor may need replacement after fault), use gL/gG 35 A. That's the fuse spec your panel designer needs for the SCCR calculation. RoHS compliance is confirmed by the substance prohibition date of 01.07.2006, covering the EU RoHS directive. No UL or CSA mark is listed in the spec record, so verify with the factory if your panel requires those for the destination jurisdiction.","metaTitle":"Siemens 3RT1016-2AF01 SIRIUS Contactor, Size S00, 10A at 24V","metaDescription":"Siemens 3RT1016-2AF01 SIRIUS power contactor, Size S00, 45mm wide, spring-loaded terminals, rated 10A at 24V, 8.5A AC-4 at 400V. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"5.5 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","at AWG cables for main contacts":"2x (24 ... 14)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"4.4 V·A","apparent pick-up power of magnet coil at AC":"27 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.8","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=97634&mlfb=3RT1016-2AF01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AF01/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"Rated operational current is 10 A at 24 V, AC-4 switching current is 8.5 A at 400 V, motor power ratings are 4.5 kW at 500 V and 5.5 kW at 690 V. Coil operates at 50/60 Hz with a pickup range of 0.8 to 1.1 times rated voltage."},{"question":"Does it mount on standard DIN rail?","answer":"Yes, it mounts via screw or snap-on onto 35 mm standard mounting rail per DIN EN 50022, and side-by-side mounting is allowed without spacing."},{"question":"What wire sizes does the spring terminal accept?","answer":"The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-2AF01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-2AF01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}