{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-2AN61","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-2AN61","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-2AN61","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AN61","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S00, 3RT1016-2AN61, 45 mm width, spring-loaded terminals, 5.5 kW at 690 V, 4.5 kW at 500 V.","salesMarkdown":"## SIRIUS Size S00 power contactor — 3RT1016-2AN61 The Siemens 3RT1016-2AN61 is a SIRIUS power contactor in the compact Size S00 frame, rated for motor switching up to 5.5 kW at 690 V and 4.5 kW at 500 V. Spring-loaded terminals on the main circuit accept 2x (0.25 to 2.5 mm²) solid or stranded conductors, matching the wiring practice on a typical DIN-rail panel. At 400 V AC-2 duty the contactor handles 4 kW, and at AC-4 (reversing or inching) it is rated 8.5 A — the AC-4 figure is the one that governs frequent jogging or plugging applications. The 24 V rated current of 10 A covers the control-circuit side; at 60 V it drops to 2 A, and at 220 V to 0.3 A, so verify the coil-supply voltage against the load curve. For type 2 coordination (no-weld protection) the required upstream fuse is 20 A gL/gG; for type 1 coordination (welding allowed but no fire hazard) it is 35 A gL/gG. Pollution degree 3 and IP20 on the front mean the contactor is suited for conventional control panels, not sealed washdown environments. Side-by-side mounting is permitted with zero clearance — no extra spacing needed between units. The 73 mm depth and 60 mm height keep the footprint compact.","metaTitle":"Siemens 3RT1016-2AN61 SIRIUS Power Contactor, Size S00, 5.5","metaDescription":"Siemens 3RT1016-2AN61 SIRIUS power contactor, Size S00, 45 mm width, spring-loaded terminals, 5.5 kW at 690 V, 4.5 kW at 500 V. Active lifecycle. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"200 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"200 ... 220 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=459221&mlfb=3RT1016-2AN61","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AN61/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1016-2AN61 and how is it quoted?","answer":"The contactor is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest functional alternative to 3RT1016-2AN61?","answer":"The 3RT1016-2AP02 is a peer in the same Size S00 frame with the same 45 mm width and spring-loaded terminals, but its coil voltage and power ratings differ — verify the coil supply and load curve before substituting."},{"question":"What is the depth of 3RT1016-2AN61?","answer":"73 mm."},{"question":"What conductor sizes does the spring-loaded terminal accept?","answer":"2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG)."},{"question":"Will 3RT1016-2AN61 drop into a panel specified for 3RT1016-2AP02?","answer":"Yes — both are Size S00, 45 mm wide, with spring-loaded terminals and snap-on DIN-rail mounting, so the mechanical footprint is identical. Only the coil voltage and power ratings differ; confirm those before the swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-2AN61","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-2AN61 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}