{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-2AN62","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-2AN62","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-2AN62","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AN62","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1016-2AN62, spring-loaded terminals, 4 kW AC-2 at 400 V, 45 mm wide, active production.","salesMarkdown":"Rated for AC-2 duty at 4 kW and AC-4 at 8.5 A, both at 400 V, this contactor handles slip-ring motor starting and plugging/reversing applications. The AC-2 figure governs the real-world motor load it can switch under normal starting conditions — that 4 kW is the number to match against your motor nameplate. Spring-loaded terminals on the main circuit accept 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). No screwdriver torque to worry about — strip, push, done. That saves time on a panel build. ## Auxiliary contact ratings and coil options The built-in auxiliary contact block carries a 24 V rated current of 10 A, dropping to 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, and 3 A at 400 V. That voltage-dependent curve means the same contact handles signal-level loads at higher voltages — useful when mixing control and indication circuits on the same contactor. Coil operates at 50 or 60 Hz with a tolerance of 0.85 to 1.1 times the rated voltage. The 200 V rated value at 50 Hz and 200–220 V at 60 Hz means it works across common European and North American control voltages without a separate transformer tap. Fuse coordination is straightforward: type 2 coordination calls for a 20 A gL/gG fuse; type 1 allows a 35 A gL/gG. That's the same as other S00 contactors in the family, so your existing panel design's fuse selection carries over. Altitude limit is 2,000 m, which covers most installations outside high-mountain sites. Typical for a control panel in a factory floor setting.","metaTitle":"Siemens 3RT1016-2AN62 SIRIUS Power Contactor, S00, 4 kW AC-2","metaDescription":"Siemens 3RT1016-2AN62 SIRIUS power contactor, size S00, 4 kW AC-2 at 400 V. Spring-loaded terminals, 45 mm wide, active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"200 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"200 ... 220 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=371325&mlfb=3RT1016-2AN62","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AN62/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1016-2AN62?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels."},{"question":"What is 3RT1016-2AN62's listed depth (73 mm) on this component line?","answer":"The depth is 73 mm, with a width of 45 mm and height of 60 mm. That 45 mm width is the critical dimension for DIN-rail spacing in a multi-contactor row."},{"question":"Will 3RT1016-2AN62 drop into a panel that was specified around 3RT1016-2AP02 without rewiring?","answer":"Yes, both are S00 frame contactors with the same 45 mm width and DIN-rail mounting. The 3RT1016-2AP02 uses screw terminals; the 2AN62 uses spring-loaded terminals. The spring-clamp version saves wiring time but the footprint and wiring positions are the same — no panel rework needed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-2AN62","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-2AN62 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}