{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-2AV01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-2AV01","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-2AV01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AV01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, power contactor, size S00, 3RT1016-2AV01, 24 VDC coil, 45 mm width, spring-loaded terminals, AC-4 8.5 A at 400 V.","salesMarkdown":"The coil pulls in at 24 VDC, and the contactor carries an AC-4 rated operating current of 8.5 A at 400 V for reversing or inching duty, and 10 A under AC-12 for resistive loads. For AC-2 and AC-3 duty at 400 V, it handles motor loads up to 4 kW. ## Mounting and wiring — panel builder notes Dimensions are 45 mm wide × 60 mm high × 73 mm deep. The 73 mm depth is the critical dimension for enclosure depth — check that your gland plate or back panel leaves clearance for the spring-loaded terminals and any wiring ducts. Main circuit connections use spring-loaded terminals accepting 2x (0.25 to 2.5 mm²) solid or stranded wire, or 2x (24 to 14 AWG). Front and terminal protection is IP20 — finger-safe but not sealed. Keep this contactor inside a cabinet rated IP54 or better if the environment has airborne dust or washdown. It is not rated for open-panel mounting in dusty areas. For Type 2 coordination (contactor remains operational after a fault), use a gL/gG 20 A fuse. This is critical for specifying the motor branch circuit — pick the coordination type based on whether you can tolerate downtime for contactor replacement. The contactor also switches DC loads: rated 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V. These are resistive DC ratings; inductive DC loads will need a diode or RC snubber across the load.","metaTitle":"Siemens 3RT1016-2AV01 SIRIUS Power Contactor, S00, 24VDC, 45","metaDescription":"Siemens 3RT1016-2AV01 SIRIUS power contactor, size S00, 24 VDC coil, 45 mm wide, spring-loaded terminals. AC-4 rated 8.5 A at 400 V. Active production. Available to order, quoted o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"400 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"400 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=217851&mlfb=3RT1016-2AV01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AV01/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of 3RT1016-2AV01?","answer":"The depth is 73 mm. This is the dimension from the DIN rail mounting surface to the front of the spring-loaded terminals — the critical clearance for enclosure depth."},{"question":"What compliance documentation is available for 3RT1016-2AV01?","answer":"As a Siemens SIRIUS catalog item, it carries CE, UL, CSA, and IEC certifications per the standard product line. RoHS and REACH declarations are available from Siemens documentation. Specific certificate numbers are not listed in this evidence set."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-2AV01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-2AV01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}