{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-2AV02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-2AV02","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-2AV02","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AV02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS series, 3RT1016-2AV02 power contactor, S00 frame, spring-loaded terminals, 400 V rated, 10 A AC-12, screw and snap-on DIN rail mount.","salesMarkdown":"## Mounting and integration The 3RT1016-2AV02: Mounts via screw or snap-on onto 35 mm DIN rail per EN 50022. The 45 mm width and 60 mm height fit a standard 6-module enclosure slot; 73 mm depth leaves clearance for front-panel wiring ducts. Side-by-side mounting is permitted without derating, so you can gang multiple contactors on a single rail for multi-motor groups. IP20 on the front and at the terminals means it's protected against finger contact but requires enclosure in a panel rated for the environment. ## Coordination and protection For Type 2 coordination (no damage after a short circuit), use a gL/gG fuse rated 20 A. For Type 1 coordination (allowable damage but safe interruption), the fuse can go up to 35 A. The degree of pollution 3 rating means the contactor is suitable for industrial environments with conductive dust or moisture — common in machine-tool and conveyor applications.","metaTitle":"Siemens 3RT1016-2AV02 SIRIUS Power Contactor, S00, 400 V, 10","metaDescription":"Siemens SIRIUS 3RT1016-2AV02 power contactor, S00 frame, 400 V rated, 10 A AC-12. Spring-loaded terminals, DIN rail mount. Current production. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"400 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"400 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=242428&mlfb=3RT1016-2AV02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2AV02/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RT1016-2AV02?","answer":"The 3RT1016-2AP02 is a sibling in the same S00 frame and coil voltage family. The key difference is the terminal type: 2AV02 uses spring-loaded terminals, while 2AP02 uses screw terminals. The spring version saves wiring time and resists loosening under vibration; the screw version is preferred where field rewiring or larger conductor sizes are expected. Both share the same mounting footprint and current ratings."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-2AV02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-2AV02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}