{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-2BP41","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-2BP41","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-2BP41","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2BP41","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1016-2BP41 power contactor, size S00, 230 V AC coil, spring-loaded terminals, 45 mm width, IP20 front, DIN rail mount.","salesMarkdown":"## Siemens SIRIUS 3RT1016-2BP41 — Power Contactor, Size S00 It carries a 230 V AC coil and uses spring-loaded terminals on the main circuit, which eliminates the need for periodic retorquing in high-vibration environments like conveyor lines or compressor skids. ## Motor Duty and Switching Capacity For motor applications, the 3RT1016-2BP41 is rated at 4.5 kW at 500 V and 5.5 kW at 690 V — typical for small-to-medium induction motors on 400/480 V or 690 V three-phase systems. AC-4 switching at 400 V is rated at 8.5 A, which governs plugging and inching applications where the contactor must interrupt stalled rotor currents. The AC-12 rating of 10 A covers resistive loads like heater banks or lighting. Auxiliary contact switching capacity is specified across the voltage range: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, and 0.3 A at 220 V DC — covering both AC and DC control circuits in the same contact block. The magnet coil draws 3.3 W during both closing and holding, which simplifies transformer sizing in the control circuit — no inrush peak beyond the steady-state value. The pickup voltage threshold is 0.85 x rated (approx. 195.5 V AC), and the dropout is at 1.1 x rated (approx. 253 V AC), giving a clear operating window on a 230 V line with typical dips. ## Wiring and Termination Spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded conductors, or 2x (24 to 14 AWG). The 6 mm side clearance to adjacent devices is the minimum recommended for heat dissipation and tool access. Depth is 73 mm, height 60 mm — compact enough for shallow enclosures. ## Protection and Coordination For Type 1 coordination (contactor may be damaged but no hazard to personnel), the fuse rating is 35 A. Pollution degree 3 means the contactor is rated for conductive pollution environments typical of industrial floors.","metaTitle":"Siemens SIRIUS 3RT1016-2BP41 Power Contactor, S00, 230 VAC C","metaDescription":"Siemens SIRIUS 3RT1016-2BP41 power contactor, size S00, 230 VAC coil, spring-loaded terminals, IP20. Current production. Rated for motor loads up to 5.5 kW at 690 V. Available to o","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"73 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","Maximum":"2 000 m","At The Side":"6 mm","Rated Value":"230 V","On The Front":"IP20","Initial Value":"0.85","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Full-scale value":"1.1","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 500 V rated value":"4.5 kW","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","Single Or Multi-Stranded":"2x (0,25 ... 2,5 mm²)","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Closing power of magnet coil at DC":"3.3 W","Holding power of magnet coil at DC":"3.3 W","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (24 ... 14)","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (24 ... 14)","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"spring-loaded terminals","at ambient temperature 40 °C rated value":"22 A","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","Type of voltage of the control supply voltage":"DC","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=212806&mlfb=3RT1016-2BP41","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2BP41/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1016-2BP41?","answer":"Submit an RFQ through this listing. Pricing and stock levels are confirmed at quote time; the part is sourced through independent distribution and quoted to order."},{"question":"What is the closest functional alternative to 3RT1016-2BP41?","answer":"The 3RT1016-1AG61 is a functional peer in the same S00 frame size, but it uses screw terminals instead of spring-loaded terminals and has a different coil voltage. The 3RT1016-2BP41's spring terminals are the deciding factor for high-vibration or maintenance-reduction applications; the 1AG61 is better suited for traditional screw-termination panels with a different control voltage."},{"question":"What is the depth of 3RT1016-2BP41?","answer":"The depth is 73 mm. Combined with a 45 mm width and 60 mm height, it fits standard shallow enclosures on DIN rail."},{"question":"What conductor sizes does the 3RT1016-2BP41 accept?","answer":"The spring-loaded terminals accept 2x (0.25 to 2.5 mm²) solid or stranded, or 2x (24 to 14 AWG). No ferrule is required but recommended for stranded conductors."},{"question":"Will 3RT1016-2BP41 drop into a panel specified around 3RT1016-1AG61 without rewiring?","answer":"Mechanically yes — both are S00 size with the same 45 mm width and DIN rail mounting. Electrically, the 2BP41 has a 230 V AC coil versus the 1AG61's different coil voltage, so the control circuit must match. The terminal type differs (spring vs. screw), which may require re-termination but not rewiring if conductors are prepared for spring-cage insertion."},{"question":"What compliance documentation is available for 3RT1016-2BP41?","answer":"The part carries a reference code per DIN EN 81346-2 (Q for power switching devices). Standard Siemens SIRIUS documentation includes the declaration of conformity for CE/UKCA, RoHS, and REACH compliance, available via the manufacturer's support portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-2BP41","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-2BP41 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}