{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1016-2GG24","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1016-2GG24","canonicalUrl":"https://aoctrl.com/siemens/3RT1016-2GG24","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2GG24","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1016-2GG24 power contactor, size S00, 4 kW AC-2 at 400 V, 8.5 A AC-4, spring-loaded terminals, screw and snap-on DIN rail mount.","salesMarkdown":"## Integrator's Sizing Note The Siemens 3RT1016-2GG24 is a SIRIUS power contactor in frame size S00, rated for 4 kW at AC-2 duty on a 400 V line — that's the motor-switching curve for slip-ring rotors or moderate inrush loads. Both main and auxiliary circuits terminate through spring-loaded terminals, so no screwdriver torque check after commissioning. Type 1 coordination (contactor may need replacement after fault) allows a 35 A gL/gG fuse.","metaTitle":"Siemens 3RT1016-2GG24 SIRIUS Contactor, Size S00, 4 kW AC-2","metaDescription":"Siemens 3RT1016-2GG24 SIRIUS power contactor, size S00. Rated 4 kW at AC-2 400 V, 8.5 A AC-4. Spring-loaded terminals, screw and snap-on DIN rail mount. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"114 mm","Solid":"2x (0.25 ... 2.5 mm²)","Width":"45 mm","Height":"60 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,25 ... 2,5 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"4.5 kW","at 60 Hz rated value":"110 V","at 690 V rated value":"5.5 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"spring-loaded terminals","at AC-2 at 400 V rated value":"4 kW","at AC-4 at 400 V rated value":"8.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","Design Of The Surge Suppressor":"with full-wave rectification","at AWG cables for main contacts":"2x (24 ... 14)","For Auxiliary And Control Circuit":"spring-loaded terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","Ambient Temperature During Operation":"-25 ... +60 °C","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (24 ... 14)","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.25 ... 1.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","Finely Stranded Without Core End Processing":"2x (0.25 ... 2.5 mm²)","apparent holding power of magnet coil at AC":"3.8 V·A","apparent pick-up power of magnet coil at AC":"3.8 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.9","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.9","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"2","number of NO contacts for auxiliary contacts instantaneous contact":"2","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=197096&mlfb=3RT1016-2GG24","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1016-2GG24/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for this contactor?","answer":"At AC-2 duty on 400 V, it is rated for 4 kW. The AC-4 switching rating is 8.5 A at 400 V, covering plugging and inching applications."},{"question":"What wire sizes does the spring-loaded terminal accept?","answer":"The main and auxiliary spring-loaded terminals accept 2x solid conductors from 0.25 to 2.5 mm², or 2x stranded conductors in the same range. AWG equivalents are 2x 24 to 14."},{"question":"What is the mounting method and panel footprint?","answer":"Screw or snap-on mounting onto 35 mm DIN rail per EN 50022. The contactor is size S00 with a width of 45 mm, height of 60 mm, and depth of 114 mm. Side-by-side mounting is permitted."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1016-2GG24","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1016-2GG24 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}