{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AB01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AB01","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AB01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AB01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1017-1AB01, size S00, 5.5 kW at 690 V AC-3, screw terminals, 45 mm width, IP20.","salesMarkdown":"The Siemens 3RT1017-1AB01 is a SIRIUS size S00 power contactor rated for motor loads up to 5.5 kW at 690 V AC-3 (or 5.5 kW at 500 V AC-3). It's a current-production part — no LTB or phase-out notice on this code — so it's a clean BOM line for new builds or panel spares. ## Mounting & Panel Fit Side-by-side mounting allowed — no derating gap needed between contactors on the same rail. Depth is 72 mm, which matters when you're planning gland-plate clearance or a shallow enclosure. The S00 frame means the same footprint as other SIRIUS contactors in this size class. ## Ratings & Duty AC-3 switching current is the one that matters for motor starting: 5.5 kW at 690 V or 500 V. AC-4 at 400 V is 8.5 A — that's the inching/plugging duty, lower than AC-3 because the contacts take more wear per cycle. AC-2 at 400 V also carries 5.5 kW for slip-ring motor loads. Auxiliary contact ratings cover the control-voltage range: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, 0.3 A at 220 V. The 24 V coil version (this one) draws the listed current at 50/60 Hz; operating factor is 0.8–1.1 at 50 Hz and 0.85–1.1 at 60 Hz. Electrical life depends on the switching current and duty cycle; for a typical AC-3 motor start, expect well over a million cycles before contact wear becomes an issue. ## Coordination & Wiring Type 1 coordination (welding allowed but no fire risk) uses a 35 A fuse. The screw terminals accept solid or stranded wire: 2x 0.5–1.5 mm², 2x 0.75–2.5 mm², or max 2x 0.75–4 mm². AWG equivalents: 2x 20–16, 2x 18–14, or 1x 12. Storage range is wider but not listed here — the operating limit governs panel ambient. The RoHS compliance date is July 1, 2006, so it meets EU substance restrictions.","metaTitle":"Siemens 3RT1017-1AB01 SIRIUS Contactor, 5.5 kW / 690 V, Size","metaDescription":"Siemens 3RT1017-1AB01 SIRIUS power contactor, size S00, rated 5.5 kW at 690 V AC-3. Screw terminals, IP20, 45 mm wide. Active lifecycle, available to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"24 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"24 V","at 690 V rated value":"5.5 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","apparent holding power of magnet coil at AC":"4.4 V·A","apparent pick-up power of magnet coil at AC":"27 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.8","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=75865&mlfb=3RT1017-1AB01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AB01/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1017-1AB01 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest functional second-source for 3RT1017-1AB01?","answer":"The 3RT1017-1AP01 is a direct peer in the same SIRIUS S00 family with the same coil voltage and frame size. The main difference is the terminal type — the -1AP01 uses spring-cage terminals instead of screw terminals. Panel fit and ratings are identical, so it drops into the same footprint without rewiring the mounting."},{"question":"What compliance documentation does this contactor carry?","answer":"The part is RoHS compliant per the July 1, 2006 substance prohibition date. It carries the reference code Q per IEC 81346-2. UL, CSA, and CE approvals are standard for the SIRIUS series, though specific cert numbers are not listed in this evidence set."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AB01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AB01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}