{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AD01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AD01","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AD01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AD01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, 3RT1017-1AD01, Size S00, 24 VDC coil, 10 A rated operational current, screw-type terminals, snap-on mounting.","salesMarkdown":"The front and terminal areas carry an IP20 rating, so it's suited for enclosed panel environments where finger-safe touch protection is needed. Compared to the 3RT1017-1AP01 which uses a 230 VAC coil, this 1AD01 variant runs on 24 VDC — a common control voltage in PLC-driven panels and safety circuits. Panel wiring is identical; the same Size S00 footprint and screw terminals mean a straight swap without rewiring the power loop. The screw terminals accept solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²). For AWG, that translates to 2x (20–16), 2x (18–14), or 1x 12. Side-by-side mounting is permitted, so multiple contactors can pack tightly on the rail without derating. For motor switching duty, the contactor is rated 5.5 kW at both 500 V and 690 V, and 5.5 kW at 400 V in AC-2 category. In the more demanding AC-4 category (frequent starts/plugging), it carries 8.5 A at 400 V. Short-circuit protection coordination: Type 1 requires a 35 A gL/gG fuse; Type 2 requires a 20 A gL/gG fuse. The coil operates reliably across a voltage range of 0.8 to 1.1 times rated at 50 Hz and 0.85 to 1.1 at 60 Hz. Substance prohibition compliance dates to July 1, 2006, aligning with RoHS requirements.","metaTitle":"Siemens 3RT1017-1AD01 SIRIUS Contactor, 24 VDC, 10 A, Size S","metaDescription":"Siemens 3RT1017-1AD01 SIRIUS power contactor, 24 VDC coil, 10 A rated current. Size S00, screw terminals, snap-on DIN rail. Sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Fastening Method":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Size Of Contactor":"S00","Solid Or Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","Product Brand Name":"SIRIUS","Degree Of Pollution":"3","Product Designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"42 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"42 V","at 690 V rated value":"5.5 kW","Side-By-Side Mounting":"Yes","For Main Current Circuit":"screw-type terminals","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Substance Prohibitance (Date)":"01.07.2006 00:00:00","at AWG cables for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","For Auxiliary And Control Circuit":"screw-type terminals","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","reference code acc. to IEC 81346-2":"Q","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","at AWG cables for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","operational current at AC-12 maximum":"10 A","number of NC contacts for main contacts":"0","number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number Of Poles For Main Current Circuit":"3","Contact Reliability Of Auxiliary Contacts":"1 faulty switching per 100 million (17 V, 1 mA)","apparent holding power of magnet coil at AC":"4.4 V·A","apparent pick-up power of magnet coil at AC":"27 V·A","Type Of Voltage Of The Control Supply Voltage":"AC","Required Spacing For Grounded Parts At The Side":"6 mm","Inductive Power Factor With Closing Power Of The Coil":"0.8","Installation Altitude At Height Above Sea Level Maximum":"2 000 m","Inductive Power Factor With The Holding Power Of The Coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","number of NC contacts for auxiliary contacts instantaneous contact":"0","number of NO contacts for auxiliary contacts instantaneous contact":"1","Of The Contactor With Added Electronically Optimized Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=519227&mlfb=3RT1017-1AD01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AD01/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RT1017-1AD01?","answer":"The 3RT1017-1AP01 is the closest functional peer — same Size S00 footprint, same screw terminals, same power ratings. The difference is the coil: 1AD01 uses 24 VDC, while 1AP01 uses 230 VAC. They drop into the same panel layout without rewiring the main circuit."},{"question":"What are the key ratings for 3RT1017-1AD01?","answer":"Rated operational current is 10 A at 24 VDC coil. Motor power ratings: 5.5 kW at 500 V and 690 V, 5.5 kW at 400 V AC-2, and 8.5 A at 400 V AC-4. Mechanical endurance is 30 million operations. Operating temperature range is -25 to +60 °C."},{"question":"Where can I buy 3RT1017-1AD01 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time. Submit a request for a firm quote on your volume."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AD01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AD01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}