{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AG62","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AG62","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AG62","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AG62","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1017-1AG62 power contactor, size S00, 24 VDC coil, 5.5 kW at AC-2 400 V, 45 mm wide, screw terminals, snap-on DIN rail mount.","salesMarkdown":"The Siemens SIRIUS 3RT1017-1AG62 is a size S00 power contactor with a 24 VDC coil rated for 10 A at 24 V. It switches motor loads up to 5.5 kW at AC-2 duty on a 400 V line, and handles 8.5 A in AC-4 reversing or plugging service. The coil holds across the 0.85 to 1.1 x Us range at both 50 and 60 Hz, so it stays pulled in through typical line sags without dropping out. Snap it onto a 35 mm DIN rail per EN 50022 or screw-mount it — the 45 mm width and 57.5 mm height fit a standard panel layout. ## Terminal & Wiring Main current circuit terminals are screw-type, accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents: 2x (20 to 16), 2x (18 to 14), or 1x 12. Strip length and torque follow the standard S00 terminal spec — no special tooling needed. ## Coordination & Protection For Type 2 coordination (no weld under fault), use a gL/gG fuse rated 20 A. For Type 1 coordination (welding allowed but no fire risk), the fuse can go up to 35 A.","metaTitle":"Siemens 3RT1017-1AG62 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens SIRIUS 3RT1017-1AG62 power contactor, size S00, 24 VDC coil, 5.5 kW at AC-2 400 V. Current lifecycle stage. Sourced to order against RFQ. 45 mm wide, DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"100 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"100 ... 110 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=508184&mlfb=3RT1017-1AG62","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AG62/alternatives.json"},"ai":{"faq":[{"question":"What is 3RT1017-1AG62's depth?","answer":"The depth is 72 mm, with a width of 45 mm and height of 57.5 mm — compact enough for dense DIN-rail layouts."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AG62","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AG62 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}