{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AH02-ZX95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AH02-ZX95","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AH02-ZX95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AH02-ZX95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1017-1AH02-ZX95, screw-type terminals, 5.5 kW at 690 V AC-3, IP20 finger-safe front, 45 mm wide, snap-on DIN rail mount.","salesMarkdown":"It mounts via screw or snap-on onto a 35 mm DIN rail per EN 50022, fitting the standard panel footprint at 45 mm wide, 57.5 mm tall, and 72 mm deep. Rated for AC-3 duty at 5.5 kW on both 500 V and 690 V supplies, this contactor handles the inrush of squirrel-cage motors up to that load — the 690 V rating is what matters for 400/690 V delta-start or IT-grid installations. The contactor carries a mechanical life of 30,000,000 operations typical, with pollution degree 3 rated for conductive environments typical of industrial enclosures. Main circuit wiring uses screw-type terminals accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded conductors — AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12. The front face and terminals carry IP20 finger-safe protection, so the contactor can sit on an open panel door during commissioning without shock risk. Side-by-side mounting is permitted with zero side clearance, which saves rail space in dense panels. The 6 mm clearance noted is for the arc chamber — not between units when ganged. For short-circuit coordination, type 1 requires a 35 A gL/gG fuse upstream; type 2 coordination drops to a 20 A gL/gG fuse to limit let-through energy and preserve the contactor after a fault. The integrated auxiliary contacts are rated 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — enough for PLC inputs or small relay coils in the control circuit. The AC-12 rating of 10 A covers resistive loads like heater contactors or signal lamps.","metaTitle":"Siemens 3RT1017-1AH02-ZX95 SIRIUS Contactor, S00, 5.5 kW at","metaDescription":"Siemens 3RT1017-1AH02-ZX95 SIRIUS power contactor, size S00, screw terminals, 5.5 kW at 690 V AC-3, IP20 front, DIN rail mount, current lifecycle stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"48 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"48 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=211464&mlfb=3RT1017-1AH02-ZX95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AH02-ZX95/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor ratings for this contactor?","answer":"AC-3 duty: 5.5 kW at 500 V and 5.5 kW at 690 V. AC-4 (reversing/plugging): 8.5 A at 400 V. AC-2 (slip-ring motors): also 5.5 kW at 400 V."},{"question":"What wire sizes does the screw terminal accept?","answer":"Solid or stranded: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). AWG: 2x (20 to 16), 2x (18 to 14), 1x 12."},{"question":"Can this contactor be mounted side-by-side with no gap?","answer":"Yes, side-by-side mounting is permitted. The 6 mm clearance noted is for the arc chamber, not between adjacent units on the rail."},{"question":"What short-circuit protection is required?","answer":"Type 1 coordination: 35 A gL/gG fuse. Type 2 coordination: 20 A gL/gG fuse to limit damage after a fault."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AH02-ZX95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AH02-ZX95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}