{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AK64-3MA0","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AK64-3MA0","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AK64-3MA0","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AK64-3MA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, Size S00, 3RT1017-1AK64-3MA0, 5.5 kW at 400 V AC-3, 24 V DC coil, screw-type terminals, snap-on DIN rail mount.","salesMarkdown":"The Siemens SIRIUS 3RT1017-1AK64-3MA0 is a Size S00 power contactor rated for 5.5 kW motor switching at both 400 V and 690 V AC-3 duty. The AC-3 rating of 5.5 kW at 400 V and 690 V means this contactor directly switches standard three-phase induction motors up to that power — a common 5.5 kW pump or conveyor motor on a 400 V line is a direct match. The AC-4 rating of 8.5 A at 400 V covers inching, plugging, or jogging duty where the contactor opens under full motor current; if your application includes frequent reversing or position stopping, that 8.5 A AC-4 figure is the one that governs contact life. The 24 V DC coil with a 10 A rated current is a standard PLC-level control signal. The coil holds reliably across the 0.85 to 1.1 x rated voltage range at 50 Hz and 0.8 to 1.1 at 60 Hz — so a 24 V supply that sags to 20.4 V still keeps the contactor sealed. The IP20 front and terminal protection means it belongs inside an enclosure, not in a washdown zone. For short-circuit coordination, the manufacturer specifies a Type 1 coordination with a 35 A gL/gG fuse and Type 2 with a 20 A gL/gG fuse. Type 2 coordination (20 A fuse) limits contactor damage to the point that it remains functional after a fault — important for high-uptime lines where you want to clear a short and restart without replacing the contactor. The 45 mm width and 57.5 mm height fit the S00 footprint — side-by-side mounting is permitted with a 6 mm spacing to adjacent devices for heat dissipation. The screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or up to 2x (0.75 to 4 mm²) stranded or solid conductors, with AWG equivalents of 2x (20-16), 2x (18-14), and 1x 12.","metaTitle":"Siemens 3RT1017-1AK64-3MA0 SIRIUS Power Contactor, Size S00,","metaDescription":"Siemens SIRIUS power contactor 3RT1017-1AK64-3MA0, Size S00, 5.5 kW at 400 V AC-3, 24 V DC coil, screw terminals, current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"111 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.8 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"110 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"120 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"2","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=59634&mlfb=3RT1017-1AK64-3MA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AK64-3MA0/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy 3RT1017-1AK64-3MA0 and get a price?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"Will 3RT1017-1AK64-3MA0 drop into a panel specified around 3RT1016-1AG61 without rewiring?","answer":"Both are Size S00 SIRIUS contactors with the same 45 mm width, 57.5 mm height, and DIN-rail mounting footprint, so mechanical fit is identical. Terminal type and wiring capacity should be verified against the specific 3RT1016 variant, but the screw-terminal design and conductor ranges are shared across the S00 family."},{"question":"What compliance documentation does Siemens provide for 3RT1017-1AK64-3MA0?","answer":"As a current-production SIRIUS component, it carries CE marking for the European market and is designed to IEC/EN 60947-4-1. UL, CSA, and other regional approvals are typically available; confirm the specific certification markings on the nameplate or request the declaration of conformity from the supplier at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AK64-3MA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AK64-3MA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}