{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AN02","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AN02","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AN02","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AN02","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS, S00 power contactor, 3RT1017-1AN02, 8.5 A AC-4 at 400 V, 5.5 kW at 400 V AC-2/AC-3, 24 VDC coil, screw terminals, 45 mm width, IP20 front.","salesMarkdown":"It carries an AC-4 rating of 8.5 A at 400 V for reversing or inching duty, and 5.5 kW at 400 V under AC-2 and AC-3 duty classes. The 24 VDC coil pulls in at nominal voltage and holds reliably across the -25 to +60 °C operating range. Side-by-side mounting is permitted with 6 mm spacing to adjacent devices, keeping panel density high. The front face carries IP20 finger protection; terminals are also rated IP20. ## AC and DC switching capability For DC loads, the contactor is rated 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — useful for switching DC solenoids, brakes, or control transformers in the same panel. The AC-12 maximum operating current is 10 A, covering resistive heating and lighting circuits. AC-4 at 400 V is 8.5 A, which governs motor reversing or plugging duty where the contacts make and break under locked-rotor current. Type 1 coordination requires a 35 A gL/gG fuse; Type 2 coordination requires 20 A gL/gG. The main circuit uses screw-type terminals accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) — AWG equivalents 2x (20-16), 2x (18-14), and 1x 12. This gives the panel builder flexibility with common wire gauges. ## Panel integration dimensions The S00 frame measures 45 mm wide, 57.5 mm high, and 72 mm deep — a compact footprint that fits standard 35 mm DIN rail enclosures. The 72 mm depth leaves clearance for wiring ducts and terminal blocks on the same rail. Operating altitude is rated to 2 000 m without derating.","metaTitle":"Siemens 3RT1017-1AN02 SIRIUS S00 Power Contactor, 8.5 A AC-4","metaDescription":"Siemens 3RT1017-1AN02 SIRIUS power contactor, size S00, 8.5 A AC-4 at 400 V, 5.5 kW AC-2/AC-3, 24 VDC coil, screw terminals, DIN rail mount, IP20 front. Current lifecycle stage. So","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"220 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=34274&mlfb=3RT1017-1AN02","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AN02/alternatives.json"},"ai":{"faq":[{"question":"What are the key switching ratings for 3RT1017-1AN02?","answer":"AC-4 at 400 V: 8.5 A for reversing/inching motor duty. AC-2/AC-3 at 400 V: 5.5 kW. DC switching: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V. AC-12 resistive maximum: 10 A."},{"question":"What is the mounting and panel footprint of 3RT1017-1AN02?","answer":"Screw or snap-on mounting onto 35 mm DIN rail per EN 50022. Dimensions: 45 mm wide, 57.5 mm high, 72 mm deep. Side-by-side mounting allowed with 6 mm spacing. Front and terminal IP20 rated."},{"question":"Where can I buy 3RT1017-1AN02 and what is the lead time?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Current availability and pricing are confirmed at quote time — submit an inquiry for a firm delivery commitment."},{"question":"Will 3RT1017-1AN02 drop into a panel specified for 3RT1016-1AG61?","answer":"Both are S00 frame contactors on 35 mm DIN rail with the same 45 mm width and screw terminal layout, so the mechanical fit and wiring pattern are identical. The difference is in coil voltage and switching ratings — verify your load current against the 3RT1017-1AN02's AC-4/AC-3 values before substitution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AN02","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AN02 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}