{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AP01-0AE6","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AP01-0AE6","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AP01-0AE6","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AP01-0AE6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1017-1AP01-0AE6, 5.5 kW at 400 V AC-2, screw terminals, 45 mm wide, snap-on DIN rail mounting.","salesMarkdown":"## Siemens 3RT1017-1AP01-0AE6 SIRIUS Power Contactor — S00 Frame, Screw Terminals For AC-4 duty (plugging, inching) at 400 V, the rated operating current is 8.5 A — the figure that governs real reversing or jogging cycles. ## Mounting and Terminal Data Screw-type terminals on the main current circuit accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or a maximum of 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12. The 72 mm depth leaves clearance behind the DIN rail for wiring ducts or backplane connections. Front protection is IP20; the terminals themselves are also rated IP20. ## Environmental Limits and Coordination This is the spec your panel designer needs for the SCCR calculation. The instantaneous auxiliary contact (1 N/O) carries 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V. At 230 V the rating is 6 A. These are the DC and AC switching limits for the control circuit — verify your PLC output or relay coil draw against these values, especially at higher voltages where the current drops off.","metaTitle":"Siemens 3RT1017-1AP01-0AE6 SIRIUS Power Contactor, S00, 5.5","metaDescription":"Siemens 3RT1017-1AP01-0AE6 SIRIUS power contactor, size S00, 5.5 kW at 400 V AC-2, screw terminals, 45 mm wide, current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=402452&mlfb=3RT1017-1AP01-0AE6","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AP01-0AE6/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 3RT1017-1AP01-0AE6?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; pricing and stock levels are confirmed at quote time."},{"question":"Will 3RT1017-1AP01-0AE6 drop into a panel specified around 3RT1016-1AG61 without rewiring?","answer":"Both are S00 frame contactors on the same 45 mm DIN-rail footprint, so the mechanical fit is identical. The terminal wire ranges overlap (2x 0.5 to 4 mm² solid/stranded). Verify the coil voltage and auxiliary contact configuration against your BOM — the 3RT1017-1AP01-0AE6 carries a 1 N/O instantaneous contact; the 3RT1016-1AG61 may differ."},{"question":"What is the depth of 3RT1017-1AP01-0AE6?","answer":"The depth is 72 mm, measured from the mounting surface to the furthest projection."},{"question":"What wire sizes does the 3RT1017-1AP01-0AE6 accept?","answer":"Screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or a maximum of 2x (0.75 to 4 mm²) solid or stranded. AWG equivalents are 2x (20 to 16), 2x (18 to 14), and 1x 12."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AP01-0AE6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AP01-0AE6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}