{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AP02-ZW95","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AP02-ZW95","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AP02-ZW95","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AP02-ZW95","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS 3RT1017-1AP02-ZW95 power contactor, Size S00, 5.5 kW at 690 V, screw terminals, 45 mm width, DIN rail snap-on mount.","salesMarkdown":"The Siemens SIRIUS 3RT1017-1AP02-ZW95 is a Size S00 power contactor, rated to switch motor loads up to 5.5 kW at both 500 V and 690 V. It carries an AC-4 rating of 8.5 A at 400 V for reversing or inching duty, and an AC-12 rating of 10 A for resistive loads. Main circuit connections use screw-type terminals. The terminal accepts solid or stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²). AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12. Depth is 72 mm, which is the dimension from the DIN rail mounting surface to the frontmost point — critical when laying out panel depth against gland plates or door-mounted components.","metaTitle":"Siemens 3RT1017-1AP02-ZW95 SIRIUS Power Contactor, Size S00,","metaDescription":"Siemens SIRIUS 3RT1017-1AP02-ZW95 power contactor, size S00, rated 5.5 kW at 690 V. Screw terminals, 45 mm wide, DIN rail mount. Current lifecycle stage. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"230 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"230 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"0","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=299794&mlfb=3RT1017-1AP02-ZW95","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AP02-ZW95/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional alternative to 3RT1017-1AP02-ZW95?","answer":"The closest functional alternative is the standard 3RT1017-1AP02 (without the -ZW95 suffix). The base contactor ratings — Size S00, 5.5 kW at 690 V, AC-4 8.5 A at 400 V — are identical. The -ZW95 suffix indicates a special version; check your Siemens documentation for what variant-specific feature it carries, but for electrical fit and mounting, the two are interchangeable."},{"question":"What compliance documentation is available for this part?","answer":"As a standard Siemens SIRIUS catalog item, this contactor carries CE marking and is designed to meet IEC/EN 60947-4-1. RoHS and REACH compliance documentation is available from Siemens. UL and CSA listings are typical for the SIRIUS line, but verify the specific -ZW95 variant's listing status against your panel certification requirements."},{"question":"Will 3RT1017-1AP02-ZW95 drop into a panel specified for 3RT1017-1AP01?","answer":"Yes, the mounting footprint and dimensions are identical — both are Size S00, 45 mm wide, snap onto 35 mm DIN rail, and share the same 72 mm depth. Terminal types and conductor capacities are the same. The difference between -1AP02 and -1AP01 is the coil voltage; verify that the -ZW95 variant's coil matches your control voltage before installation."},{"question":"What is the depth of 3RT1017-1AP02-ZW95?","answer":"The depth is 72 mm, measured from the DIN rail mounting surface to the frontmost point of the contactor."},{"question":"What conductor sizes does the terminal accept?","answer":"Screw-type terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AP02-ZW95","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AP02-ZW95 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}