{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AQ64","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AQ64","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AQ64","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AQ64","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1017-1AQ64, 24 VDC coil, 10 A rated operational current at 24 V, screw-type terminals, 35 mm DIN rail mount.","salesMarkdown":"The 24 VDC coil pulls in reliably across a 0.85 to 1.1 times rated voltage at 50 Hz and 0.8 to 1.1 at 60 Hz. At 24 V the main contacts are rated 10 A; for motor duty at 500 V it handles 5.5 kW, and at 690 V also 5.5 kW. Front protection is IP20, so it's safe for finger contact inside an enclosed panel. The 10 A rating at 24 V is the maximum thermal current (AC-12) for the main contacts — that's the resistive load limit. For motor starting (AC-3), the practical limit is the 5.5 kW figure at 500 V or 690 V. Short-circuit coordination is specified: type 2 coordination requires a gL/gG fuse rated 20 A; type 1 coordination allows a 35 A fuse. That means with a 20 A fuse upstream, the contactor remains usable after a fault (type 2). Pick your fuse based on whether downtime for contactor swap is acceptable. Mechanical endurance is 30 million switching cycles — that's the contactor body life before wear-out, not the electrical life under load. Electrical life depends on the switched current and category; for a 5.5 kW motor started once per minute, expect several hundred thousand operations before contact inspection. ## Integration notes Terminals are screw-type for the main circuit, accepting 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded wire. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12. Strip length is standard for the terminal design — no special tooling needed beyond a screwdriver. The contactor has 2 instantaneous auxiliary contacts (form C or form A depends on the specific variant — check the full order code suffix for the auxiliary configuration). These are rated for switching at various voltages: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, 3 A at 400 V.","metaTitle":"Siemens 3RT1017-1AQ64 SIRIUS Power Contactor, S00, 24 VDC 10","metaDescription":"Siemens 3RT1017-1AQ64 SIRIUS power contactor, size S00. 24 VDC coil, rated 10 A at 24 V, 5.5 kW motor at 500 V. Screw terminals, 35 mm DIN rail mount. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"111 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.85 ... 1.1","at 60 Hz":"0.8 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"220 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"264 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"2","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"5.1 V·A","Apparent pick-up power of magnet coil at AC":"31.7 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.77","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=139499&mlfb=3RT1017-1AQ64","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AQ64/alternatives.json"},"ai":{"faq":[{"question":"Will the 3RT1017-1AQ64 drop into a panel specified around the 3RT1017-1AP01 without rewiring?","answer":"Both are SIRIUS S00 frame contactors with the same physical footprint — 45 mm width, 57.5 mm height, 111 mm depth — and both use screw-type terminals on the same DIN rail mount. The difference is the coil voltage: the 1AQ64 has a 24 VDC coil, while the 1AP01 has a different coil voltage. If the panel was wired for 24 VDC control, the 1AQ64 is a direct mechanical swap; if the original coil voltage differs, the coil circuit needs rewiring. The main power terminals and auxiliary contact positions are identical."},{"question":"What wire sizes does the 3RT1017-1AQ64 accept?","answer":"The screw-type main terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded conductors. AWG equivalents are 2x (20 to 16), 2x (18 to 14), or 1x 12."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AQ64","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AQ64 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}