{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3RT1017-1AV01","brand":"Siemens","brandSlug":"siemens","productSlug":"3RT1017-1AV01","canonicalUrl":"https://aoctrl.com/siemens/3RT1017-1AV01","factsUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AV01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIRIUS power contactor, size S00, 3RT1017-1AV01, 24 VDC coil, 10 A at 24 V, screw terminals, DIN rail mount, IP20.","salesMarkdown":"Rated for a 24 VDC coil, it carries 10 A at 24 V (AC-12 resistive load) and can switch motor loads up to 5.5 kW at 500 V or 690 V. For heavy-duty jogging or inching (AC-4 duty at 400 V), the rated operational current is 8.5 A — the figure that governs real reversing or plugging applications. The AC-4 rating of 8.5 A at 400 V is the limiting value for frequent motor reversals or inching — the AC-3 rating (not listed here) would be higher, but AC-4 is the one that matters when the contactor sees high electrical wear. For coordinated protection, Type 2 coordination requires a gL/gG fuse of 20 A; Type 1 allows up to 35 A. These fuse limits define the maximum prospective fault current the contactor can clear without damage to downstream components. The contactor accepts solid and stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and up to 2x (0.75 to 4 mm²) maximum, with AWG equivalents of 2x (20 to 16) and 2x (18 to 14) plus a single 12 AWG. This contactor is a standard building block in motor control centers, conveyor drives, pump panels, and HVAC compressor starters. The size S00 frame keeps the footprint small — 45 mm wide — so it fits tightly packed DIN-rail assemblies. Side-by-side mounting is permitted, which means no mandatory spacing gaps between units, saving rail space in dense panels. If a customer's AVL requires a functionally equivalent alternate, the 3RT1017-1AP01 is the closest peer — same size S00 frame, same 24 VDC coil, same screw terminals, and same 45 mm width. The difference is in the auxiliary contact configuration; verify the customer's wiring diagram before substituting. Any change from the specified order code should follow the customer's deviation process.","metaTitle":"Siemens 3RT1017-1AV01 SIRIUS Power Contactor, Size S00, 24 V","metaDescription":"Siemens 3RT1017-1AV01 SIRIUS power contactor, size S00, 24 VDC coil, 10 A rated at 24 V. Active production. Screw terminals, DIN rail mount. IP20 front. Sourced to order against RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Contactors"],"specifications":{"Depth":"72 mm","Solid":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)","Width":"45 mm","Height":"57.5 mm","Maximum":"2 000 m","at 50 Hz":"0.8 ... 1.1","at 60 Hz":"0.85 ... 1.1","At The Side":"6 mm","On The Front":"IP20","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Mounting type":"screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022","Of The Terminal":"IP20","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","Size of contactor":"S00","Product brand name":"SIRIUS","Degree of pollution":"3","Product designation":"power contactor","at 24 V rated value":"10 A","at 60 V rated value":"2 A","Of Contactor Typical":"30 000 000","at 110 V rated value":"1 A","at 220 V rated value":"0.3 A","at 230 V rated value":"6 A","at 400 V rated value":"3 A","at 50 Hz rated value":"400 V","at 500 V rated value":"5.5 kW","at 60 Hz rated value":"400 V","at 690 V rated value":"5.5 kW","Instantaneous Contact":"1","Side-by-side mounting":"Yes","For Main Current Circuit":"screw-type terminals","Single Or Multi-Stranded":"2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)","at AC-2 at 400 V rated value":"5.5 kW","at AC-4 at 400 V rated value":"8.5 A","Operating current at AC-12 maximum":"10 A","With Type Of Assignment 2 Required":"fuse gL/gG: 20 A","at AWG conductors for main contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","With Type Of Coordination 1 Required":"fuse gL/gG: 35 A","Reference code acc. to DIN EN 81346-2":"Q","Number of NC contacts for main contacts":"0","Number of NO contacts for main contacts":"3","Finely Stranded With Core End Processing":"2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)","Number of poles for main current circuit":"3","at AWG conductors for auxiliary contacts":"2x (20 ... 16), 2x (18 ... 14), 1x 12","Contact reliability of auxiliary contacts":"1 faulty switching per 100 million (17 V, 1 mA)","For Auxiliary And Control Current Circuit":"screw-type terminals","at ambient temperature 40 °C rated value":"22 A","Apparent holding power of magnet coil at AC":"4.4 V·A","Apparent pick-up power of magnet coil at AC":"27 V·A","Type of voltage of the control supply voltage":"AC","Inductive power factor with closing power of the coil":"0.8","Inductive power factor with the holding power of the coil":"0.27","Of The Contactor With Added Auxiliary Switch Block Typical":"10 000 000","For Short-Circuit Protection Of The Auxiliary Switch Required":"fuse gL/gG: 10 A","Of The Contactor With Added Electronics-Compatible Auxiliary Switch Block Typical":"5 000 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$45.36","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=109962&mlfb=3RT1017-1AV01","alternativesUrl":"https://aoctrl.com/api/mcp/products/3RT1017-1AV01/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to the 3RT1017-1AV01?","answer":"The 3RT1017-1AP01 is the closest functional peer — same size S00 frame, same 24 VDC coil, same screw terminals, and same 45 mm width. The difference is in the auxiliary contact arrangement, so verify the wiring diagram before substituting."},{"question":"What is the depth of the 3RT1017-1AV01?","answer":"The depth is 72 mm."},{"question":"What conductor sizes does the 3RT1017-1AV01 accept?","answer":"It accepts solid and stranded conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and up to 2x (0.75 to 4 mm²) maximum. AWG equivalents are 2x (20 to 16) and 2x (18 to 14) plus a single 12 AWG."},{"question":"Will the 3RT1017-1AV01 drop into a panel specified around the 3RT1017-1AP01 without rewiring?","answer":"Mechanically yes — both are size S00, 45 mm wide, and mount on 35 mm DIN rail with screw terminals. However, the auxiliary contact configuration may differ, so the control wiring may need adjustment. Always compare the auxiliary contact arrangement on the nameplate before assuming drop-in compatibility."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/3RT1017-1AV01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/3RT1017-1AV01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}